AGILENT 8482A REPAIR and AGILENT 8482A CALIBRATION

 
Custom-Cal has a high success rate in the repair of the AGILENT 8482A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the AGILENT 8482A Calibration. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another RF Power Sensor? Shop for Comparable Products on our  used RF Power Sensor page

 
   AGILENT 8482A   Description / Specification:    
AGILENT 8482A 4.2 GHz Thermocouple Power Sensor

The HP 8482A 50-ohm silicon monolithic thermocouple Power Sensor gives you extremely low SWR even at mm-wave frequencies. Low SWR translates into minimum mismatch uncertainty and optimum measurement accuracy. The Agilent 8482A power sensor is designed for use with the E4418A/B, E4419A/B, 435B, 436A, 437B, 438A, 70100A and E1416A power meters. Frequency range: 100 kHz to 4.2 GHz. Maximum SWR: 100 to 300 kHz; 1.60, 0.3 to 1 MHz; 1.20, 1MHz to 2GHz; 1.10, 2 to 4.2 GHz; 1.30. Power of range: 0.3 microW to 100 mW(-30 to +20 dBm). Maximum power: 300 mW average, 15 W peak, 30W - us per pulse. Power Linearity: +10 to +20 dBm + 2, - 4%. Connector type: Type-N(m).



 

Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Clipping
Clipping is the limiting of a signal so that it never exceeds some threshold.

Modulation
Modulation is the coding of information onto the carrier frequency. This includes amplitude, frequency, or phase modulation techniques.

Sensitivity
Sensitivity is the smallest signal that can reliably detected. Sensitivity specifies the strength of the smallest signal at the input that causes the output signal power to be M times the output noise power where M must be specified. M=1 is very popular

Please contact us for your AGILENT 8482A REPAIR and/or AGILENT 8482A CALIBRATION

Standard Calibration $125.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of this model. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.

I'm interested in: 
 
Calibration Type (Select one):


 
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 
 (*) Required Fields    For formal quote please fill in all fields.
From (Email):*
Contact Name:*
Company:
Address 1:
Address 2:
City:
State/Territory/Province:
Zip/Postal Code:
Country:*
Phone:*

 
Comment:
 
 
Datasheet available, Serving customers in Alabama AL Arizona AZ Arkansas AR California CA Colorado CO Connecticut CT Delaware DE Florida FL Georgia GA Hawaii HI Idaho ID Illinois IL Indiana IN Iowa IA Kansas KS Kentucky KY Louisiana LA Maine ME Maryland MD Massachusetts MA Michigan MI Minnesota MN Mississippi MS Missouri MO Montana MT Nebraska NE Nevada NV New Hampshire NH New Jersey NJ New Mexico NM New York NY North Carolina NC North Dakota ND Ohio OH Oklahoma OK Oregon OR Pennsylvania PA Rhode Island RI South Carolina SC South Dakota SD Tennessee TN Texas TX Utah UT Vermont VT Virginia VA Washington WA West Virginia WV Wisconsin WI Wyoming WY Canada China Denmark Germany Hong Kong India Israel Italy Japan Mexico Spain Thailand United Kingdom