Talk to the Experts

Phone: 888-530-9009 | Email: sales@custom-cal.com

      Find Your Product
RSS    LinkedIn    RSS

TEKTRONIX THS730A REPAIR and TEKTRONIX THS730A CALIBRATION

 
Custom-Cal has a high success rate in the repair of the TEKTRONIX THS730A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the TEKTRONIX THS730A Calibration. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope? Shop for Comparable Products on our  used Oscilloscope page
   TEKTRONIX THS730A (THS 730A)   Description / Specification:      
TEKTRONIX THS730A

200 MHz handheld battery operated Oscilloscope/DMM. Channels: Two. Sample Rate (Each Channel) 1 GS/s. Time/Division Range: 2 ns to 50 s/div. Sensitivity: 5 mV to 50 V/div (to 500 V/div with 10X probe). Position Range: ± 10 div. DC Gain Accuracy: ±2%. Vertical Resolution: 8-Bits. Record Length: 2500 points. Horizontal Accuracy: ±200 ppm. Roll Mode: >= 0.5 s/div. Autorange: User-selectable. Trigger Modes: Auto, Normal. DMM Specs; DC Voltage Ranges: 400.0 mV to 880 V. DC Volts Accuracy: ±(0.5% of reading + 5 counts). True RMS AC Voltage Ranges: 400.0 mV to 640 V. Maximum Float Voltage: 600 VRMS CAT II, each channel (probe dependent). Resolution: 4000 count, 3-3/4 digits. AC Volts Accuracy: ±(2% of reading + 5 counts). Resistance Ranges - 400.0 ohm to 40.00 M-Ohm. Resistance Accuracy: ±(0.5% of reading + 2 counts); 40 M-Ohm: ±(2% of reading + 5 counts). Diode Test Range: 0 to 2 V. Backlit LCD (320x240)



 

 

Please contact us for your TEKTRONIX THS730A REPAIR and/or TEKTRONIX THS730A CALIBRATION

Standard Calibration $125.00. * *This is a Web introductory price for one calibration of this model. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.
I'm interested in: 
 
Calibration Type (Select one):


 
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 
 (*) Required Fields    For formal quote please fill in all fields.
From (Email):*
Contact Name:*
Company:
Address 1:
Address 2:
City:
State/Territory/Province:
Zip/Postal Code:
Country:*
Phone:*

 
Comment:
 
 
Datasheet available, Serving customers in Alabama AL Arizona AZ Arkansas AR California CA Colorado CO Connecticut CT Delaware DE Florida FL Georgia GA Hawaii HI Idaho ID Illinois IL Indiana IN Iowa IA Kansas KS Kentucky KY Louisiana LA Maine ME Maryland MD Massachusetts MA Michigan MI Minnesota MN Mississippi MS Missouri MO Montana MT Nebraska NE Nevada NV New Hampshire NH New Jersey NJ New Mexico NM New York NY North Carolina NC North Dakota ND Ohio OH Oklahoma OK Oregon OR Pennsylvania PA Rhode Island RI South Carolina SC South Dakota SD Tennessee TN Texas TX Utah UT Vermont VT Virginia VA Washington WA West Virginia WV Wisconsin WI Wyoming WY Canada China Denmark Germany Hong Kong India Israel Italy Japan Mexico Spain Thailand United Kingdom