Talk to the Experts

Phone: 888-530-9009 | Email: sales@custom-cal.com

      Find Your Product
RSS    LinkedIn    RSS

NEWPORT 8000 CALIBRATION and NEWPORT 8000 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the NEWPORT 8000 Calibration. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Laser Diode Controller? Shop for Comparable Products on our  used Laser Diode Controller page

 
   NEWPORT 8000   Description / Specification:    
NEWPORT 8000 4-Ch Modular Laser Diode Controller

The Newport 8000 4 channel Modular Mainframe Controller accepts: Temperature Controller (TEC) Modules; 40 Watt (5A/8V), ultra stable bipolar output. Thermistor, AD590, LM335, and Pt RTD sensors. Dual Temperature Controller Modules; Two independent outputs per module. 2.5 Amps at 6 Volts (15 Watt). Laser Diode Driver (LDD) Modules; 200 mA to 6 Amp low noise outputs. External analog modulation. Adjustable photodiode bias voltage. Comprehensive laser diode protection features. MOPA Laser Diode Driver Module; 500 mA LDD for master oscillator section. 4 Amp LDD for power amplifier section. Connector for TEC module input. Combination LDD/TEC Modules; Internal function generator, (Waveforms: Sine & square wave. Frequency Range: 200 Hz to 2 kHz and 200 Hz to 2 kHz). 2.5 Amps at 6 Volts (15 Watt) highly stable TEC. 200 mA to 2 Amp low noise LDD. Dual Laser Diode Driver (LDD) Module; Two independent outputs per module. 100 to 1,000 mA per channel. Display; Type: LCD graphics display, 240 (W) x 128 (H) pixels. Back Lighting: Green LED. Controls: Brightness and Contrast (contrast optimizes viewing angle). Channel Active: Green LASER ACTIVE LED indicates that at least one Laser Diode output is on and the LCD graphics shows details of active channels. GPIB/IEEE 488.2 and RS-232C Interface



 

   
Standard Calibration $75.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the NEWPORT 8000. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Optical Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Amplified Spontaneous Emission Source (ASE)
ASE, a process where spontaneously emitted radiation (luminescence) is amplified. In lasers and particularly in high-gain erbium-doped amplifiers, amplified spontaneous emission is usually an unwanted effect. It tends to limit the gain achievable in a single stage of a fiber optic amplifier to the order of 40–50 dB.

Dynamic Range
In a transmission system, the ratio of the overload level to the noise level of the system, usually expressed in dB. Ratio of the highest to lowest detectable signal of a system, expressed in dB.

Optical Power
Optical Power is usually measured in "dBm", or decibels referenced to one miliwatt of power. while loss is a relative reading, optical power is an absolute measurement, referenced to standards. You measure absolute power to test transmitters or receivers and relative power to test loss.

Relative Wavelength Accuracy
When randomly changing the wavelength and measuring the differences between the actual and displayed wavelengths, the relative wavelength accuracy is ± half the span between the maximum and the minimum value of all differences.

Wavelength
Wavelength is a term for the color of light, usually expressed in nanometers (nm) or microns (m). In Fiber Optics the wavelenghts mostly used are in the infrared region where the light is invisible to the human eye.


Please contact us for your NEWPORT 8000 CALIBRATION and/or NEWPORT 8000 4-Ch Modular Laser Diode Controller REPAIR

I'm interested in: 
 
Calibration Type (Select one):


 
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 
 (*) Required Fields    For formal quote please fill in all fields.
From (Email):*
Contact Name:*
Company:
Address 1:
Address 2:
City:
State/Territory/Province:
Zip/Postal Code:
Country:*
Phone:*

 
Comment:
 
 
Repair and Calibration of Fiber Optic Instruments - Optical Spectrum Analyzer OSA, Laser Source (DFB-LD-WDM-BBS), OTDR, Optical Power Meter, Tunable Laser Source (TLS), Wavelength Meter. Repair and Calibration of RF Instruments - Network Analyzer SNA VNA, Spectrum Analyzer, Signal Generator Signal Analyzer, Frequency Counter, Power Meter. Test Equipment Datasheet