86120 Repair / Service E14, E7, E4, E34
|
Custom-Cal is now offering an exclusive three year warranty on HP / Agilent 86120A, 86120B and 86120C repairs. In addition, we offer the following
personalized service:
• Free evaluation of 86120A 86120B and 86120C models.
• One day turn around when your situation demands it.
• A $500 discount (when money is tight) by opting for a standard one year warranty.
• We also have both 86120B and 86120C units in stock for immediate delivery, whether for purchase or rental
Custom-Cal has in depth experience having repaired over 1000 86120’s with a success rate of over 99%.. Our typical repair time is less
than 5 business days as we have most replacement parts in stock. We repair the E14 error using NEW, original manufacturer
parts; which come with a one year manufacturer warranty which we will extend for three years. We don't use refurbished, or cheap generic parts.
Custom-Cal is known as an independent optical test equipment repair lab.
|
86120 Series Comparison
|
Agilent 86120A
|
Agilent 86120B
|
Agilent 86120C
|
|
|
|
700 nm to 1650 nm, Multi-Wavelength Meter.
±3 ppm wavelength accuracy and 20 GHz wavelength resolution.
+18 dBm Maximum safe input level (sum of all lines)
Measure any of the following parameters:
• Up to 100 laser lines simultaneously
• Wavelengths and powers
• Average wavelength
• Total optical power
• Laser line separation
• Laser drift (wavelength and power)
• Signal- to-noise ratios
• Coherence length
Additional Agilent 86120A Specs
|
700 nm to 1650 nm, Multi-Wavelength Meter.
±3 ppm wavelength accuracy and 20 GHz wavelength resolution.
+18 dBm Maximum safe input level (sum of all lines)
Measure any of the following parameters:
• Up to 100 laser lines simultaneously
• Wavelengths and powers
• Average wavelength
• Total optical power
• Laser line separation
• Laser drift (wavelength and power)
• Signal- to-noise ratios
• Coherence length
Additional Agilent 86120B Specs
86120B User Manual
|
1270 nm to 1650 nm, Multi-Wavelength Meter.
±2 ppm wavelength accuracy and 10 GHz wavelength resolution.
+18 dBm Maximum safe input level (sum of all lines)
Measure any of the following parameters:
• Up to 200 laser lines simultaneously
• Wavelengths and powers
• Average wavelength
• Total optical power
• Laser line separation
• Laser drift (wavelength and power)
• Signal- to-noise ratios
• Fabry- Perot lasers
Additional Agilent 86120C Specs
86120C User Manual
|
Common Errors:
E14 (ERROR 14) "DATA ACQUISITION PROBLEM" or "DATA ACQUISITION ERROR"
E4 (ERROR 4) "MOTOR INDEX PULSE NOT FOUND"
E7 (ERROR 7) "MOTOR NOT SETTLED"
E34 (ERROR 34) "BATTERY FAILED"
|
Options:
010 Delete FC/PC connector
011 Diamond HMS-10 connector interface (B/C only)
013 DIN 47256 connector interface (B/C only)
014 ST connector interface (B/C only)
017 SC connector interface (B/C only)
022 Replace flat physical contact interface with angled physical contact interface
412 Add 10 dB external attenuator (FC/PC interface connector)
417 FC/APC Connector (requires Option 022) (B/C only)
|
|
Select:
|
|
|
|