TEKTRONIX THS730A REPAIR and TEKTRONIX THS730A CALIBRATION

 
Custom-Cal has a high success rate in the repair of the TEKTRONIX THS730A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the TEKTRONIX THS730A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope?
Shop for Comparable Products on our
 used Oscilloscope page

 
   TEKTRONIX THS730A (THS 730A)   Description / Specification:    
TEKTRONIX THS730A

200 MHz handheld battery operated Oscilloscope/DMM. Channels: Two. Sample Rate (Each Channel) 1 GS/s. Time/Division Range: 2 ns to 50 s/div. Sensitivity: 5 mV to 50 V/div (to 500 V/div with 10X probe). Position Range: ± 10 div. DC Gain Accuracy: ±2%. Vertical Resolution: 8-Bits. Record Length: 2500 points. Horizontal Accuracy: ±200 ppm. Roll Mode: >= 0.5 s/div. Autorange: User-selectable. Trigger Modes: Auto, Normal. DMM Specs; DC Voltage Ranges: 400.0 mV to 880 V. DC Volts Accuracy: ±(0.5% of reading + 5 counts). True RMS AC Voltage Ranges: 400.0 mV to 640 V. Maximum Float Voltage: 600 VRMS CAT II, each channel (probe dependent). Resolution: 4000 count, 3-3/4 digits. AC Volts Accuracy: ±(2% of reading + 5 counts). Resistance Ranges - 400.0 ohm to 40.00 M-Ohm. Resistance Accuracy: ±(0.5% of reading + 2 counts); 40 M-Ohm: ±(2% of reading + 5 counts). Diode Test Range: 0 to 2 V. Backlit LCD (320x240)



 

Standard Calibration $160.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the TEKTRONIX THS730A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Averaging
Averaging is a mathematical process to reduce the variation in a measurement by summing the data points from multiple measurements and dividing by the number of points summed.

Fall Time
Fall time is the time required for the amplitude of a pulse to decrease (fall) from a specified value (usually 90 percent of the peak value exclusive of overshoot or undershoot) to another specified value (usually 10 percent of the maximum value exclusive of overshoot or undershoot).

Noise Density
Noise Density is the amount of noise within a defined bandwidth, usually normalized to 1 Hz.

Resolution Bandwidth (RBW)
Resolution Bandwidth (RBW) is the minimum bandwidth over which you can separate two signals and still see them.


Please contact us for your TEKTRONIX THS730A REPAIR and/or TEKTRONIX THS730A CALIBRATION

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: