TEKTRONIX TDS1001 CALIBRATION and TEKTRONIX TDS1001 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the TEKTRONIX TDS1001 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope?
Shop for Comparable Products on our
 used Oscilloscope page

 
   TEKTRONIX TDS1001   Description / Specification:   Spec Sheet 
TEKTRONIX TDS1001 2 Ch 40 MHz Digital Storage Oscilloscope

40 MHz Digital Storage Oscilloscope, Two Channel. Sample Rate on Each Channel: 1.0 GS/s. Maximum Record Length: 2.5K points. Vertical Resolution: 8–bits. Vertical Sensitivity: 2 mV to 5 V/div. Vertical Accuracy: ±3%. Max Input Voltage: 300 VRMS CAT II; derated at 20 dB/decade above 100 kHz to 13 Vpk-pk AC at 3 MHz and above. Position Range 2 mV to 200 mV/div ±2 V; >200 mV to 5 V/div ±50 V. Bandwidth Limit: 20 MHz. Input Coupling: AC, DC, GND. Input Impedance Selections: 1 megaohm in parallel with 20 pF. Time Base Range: 5 ns - 50 s/div. Accuracy: 50 ppm. Acquisition Modes; Peak Detect – High frequency and random glitch capture. Captures glitches as narrow as 12 ns (typical) using acquisition hardware at all time/div settings from 5 µs/div to 50 s/div. Sample – Sample data only. Average – Waveform averaged, selectable: 4, 16, 64, 128. Single Sequence – Use the Single Sequence button to capture a single triggered acquisition sequence at a time. Trigger Modes – Auto, Normal, Single Sequence. Trigger Types; Edge (rising or falling) – Conventional level-driven trigger. Positive or negative slope on any channel. Coupling selections: AC, DC, Noise Reject, HF Reject, LF Reject. Video – Trigger on all lines or individual line, odd/even or all fields from composite video or broadcast standards (NTSC, PAL, SECAM). Pulse Width (or Glitch) – Trigger on a pulse width less than, greater than, equal to, or not equal to a selectable time limit ranging from 33 ns to 10 s. Trigger Source: CH1, CH2, Ext, Ext/5, AC Line. Monochrome, 1/4 VGA, backlit passive LCD with adjustable multi-level contrast and inverse video selectable from front panel.



 

Standard Calibration $160.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the TEKTRONIX TDS1001. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Carrier Wave (CW)
Carrier Wave or Continuous Wave is a sinusoidal signal without modulation.

Harmonic
A harmonic of a wave is a component frequency of the signal that is an integer multiple of the fundamental frequency, i.e. if the fundamental frequency is f, the harmonics have frequencies 2f, 3f, 4f, . . . etc.

Noise Floor
Noise floor is the measure of the signal created from the sum of all the noise sources and unwanted signals within a measurement system.

Ripple
Ripple is the small unwanted residual periodic variation of the direct current (dc) output


Please contact us for your TEKTRONIX TDS1001 CALIBRATION and/or TEKTRONIX TDS1001 2 Ch 40 MHz Digital Storage Oscilloscope REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: