A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the TEKTRONIX TDS1002B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope?
Shop for Comparable Products on our
 used Oscilloscope page

 
   TEKTRONIX TDS1002B   Description / Specification:   Spec Sheet 
TEKTRONIX TDS1002B 2 Ch 60 MHz Digital Storage Oscilloscope

The Tektronix TDS1002B is a 60 MHz Digital Storage Oscilloscope, Two Channel. Sample Rate on Each Channel: 1.0 GS/s. Maximum Record Length: 2.5K points. Vertical Resolution: 8–bits. Vertical Sensitivity: 2 mV to 5 V/div. Vertical Accuracy: ±3%. Max Input Voltage: 300 VRMS CAT II; derated at 20 dB/decade above 100 kHz to 13 Vpk-pk AC at 3 MHz. Position Range 2 mV to 200 mV/div ±2 V; >200 mV to 5 V/div ±50 V. Bandwidth Limit: 20 MHz. Input Coupling: AC, DC, GND. Input Impedance: 1 megaohm in parallel with 20 pF. Time Base Range: 5 ns - 50 s/div. Accuracy: 50 ppm. Acquisition Modes; Peak Detect – High-frequency and random-glitch capture. Captures glitches as narrow as 12 ns (typical) at all time base settings from 5 µs/div to 50 s/div. Sample – Sample data only. Average – Waveform averaged, selectable: 4, 16, 64, 128. Single Sequence – Use the Single Sequence button to capture a single triggered acquisition sequence. Trigger Modes – Auto, Normal, Single Sequence. Trigger Types; Edge (rising or falling) – Conventional level-driven trigger. Positive or negative slope on any channel. Coupling selections: AC, DC, Noise Reject, HF Reject, LF Reject. Video – Trigger on all lines or individual line, odd/even or all fields from composite video or broadcast standards (NTSC, PAL, SECAM). Pulse Width (or Glitch) – Trigger on a pulse width less than, greater than, equal to, or not equal to a selectable time limit ranging from 33 ns to 10 s. Trigger Source: CH1, CH2, Ext, Ext/5, AC Line. Monochrome, 1/4 VGA, backlit passive LCD with adjustable multi-level contrast and inverse video selectable from front panel



 

Standard Calibration $160.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the TEKTRONIX TDS1002B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Channel Bandwidth
Channel Bandwidth is the bandwidth over which power is measured. This is usually the bandwidth in which almost all of the power of a signal is contained.

Jitter
Jitter in technical terms is the deviation in or displacement of some aspect of the pulses in a high-frequency digital signal. Jitter is the time variation of a periodic signal in electronics and telecommunications, often in relation to a reference clock source. Jitter may be observed in characteristics such as the frequency of successive pulses, the signal amplitude, or phase of periodic signals. Jitter is a significant, and usually undesired, factor in the design of almost all communications links (e.g., USB, PCI-e, SATA, OC-48). In clock recovery applications it is called timing jitter.

Overshoot
Overshoot is the distortion that follows a major transition; the difference between the peak power point and the pulse-top amplitude computed as a percentage of the pulse-top amplitude.

Rise Time
Rise time refers to the time required for a signal to change from a specified low value to a specified high value, usually 10 and 90 percent of pulse-top amplitude (vertical display is linear power).


Please contact us for your TEKTRONIX TDS1002B CALIBRATION and/or TEKTRONIX TDS1002B 2 Ch 60 MHz Digital Storage Oscilloscope REPAIR

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: