FLUKE 289 CALIBRATION and FLUKE 289 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the FLUKE 289 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Multimeter DMM?
Shop for Comparable Products on our
 used Multimeter DMM page

 
   FLUKE 289   Description / Specification:    
FLUKE 289 True-rms Industrial Logging Multimeter with TrendCapture

The Fluke 289 True-rms Industrial Logging Multimeter with TrendCapture maximizes plant productivity in the most demanding industrial settings. Solve problems on motor drives, in-plant automation, power distribution and electro-mechanical equipment. It has a large 50,000 count, 1/4 VGA display with white backlight for fast, accurate viewing of measurements. The Logging Function with TrendCapture plots measurements as a single line to help detect anomalies over time, storing up to 10,000 readings. Using on-board TrendCapture, you can graphically view logged readings on the meter. Specifications. DC Volts Range & Resolution: 50.000 mV, 500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0 V. DC Volts Basic Accuracy: 0.025 %. AC Volts Range & Resolution: 50.000 mV, 500.00 mV, 5.0000 V, 50.000 V, 500.00 V, 1000.0 V. DC Volts Basic Accuracy: 0.4 % (true-rms). DC Current Range & Resolution: 500.00 µA, 5000.0 µA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A. DC Current Basic Accuracy: 0.15 %. AC Current Range & Resolution: 500.00 µA, 5000.0 µA, 50.000 mA, 400.00 mA, 5.0000 A, 10.000 A. AC Current Basic Accuracy: 0.7 % (true-rms). Temperature (excluding probe): -200.0 °C to 1350.0 °C (-328.0 °F to 2462.0 °F). Temperature Basic Accuracy: 1.0 %. Resistance Range & Resolution: 50.000 ohm, 500.00 ohm, 5.0000 kohm, 50.000 kohm, 500.00 kohm, 5.0000 Mohm, 50.00 Mohm, 500.0 Mohm. Resistance Basic Accuracy: 0.05 %. Capacitance Range & Resolution: 1.000 nF,10.00 nF 100.0 nF, 1.000 µF, 10.00 µF, 100.0 µF, 1000 µF, 10.00 mF, 100.00 mF. Capacitance Basic Accuracy: 1.0 %. Frequency Range & Resolution: 99.999 Hz, 999.99 Hz, 9.9999 kHz, 99.999 kHz, 999.99 kHz. Frequency Basic Accuracy: 0.005 %. Continuity/Diode Conductance: 0.01 nS to 50.00 nS (20 Mohm to 100 Gohm). Resistance Low Ohm: (0.001 ohm to 50.000 ohm 10 mA source).



 

Standard Calibration $115.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the FLUKE 289. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Crest Factor
Crest factor or peak-to-average ratio (PAR) is a measurement of a waveform, calculated from the peak amplitude of the waveform divided by the RMS value of the waveform

Linearity
Linearity is the relative difference between the displayed power ratio, Dx/D0, and the actual (true) power ratio Px/P0 caused by changing the displayed power level from the reference level, D0, to an arbitrary displayed level, Dx.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.

Sensitivity
Sensitivity is the minimum magnitude of input signal required to produce a specified output signal having a specified signal-to-noise ratio, or other specified criteria.


Please contact us for your FLUKE 289 CALIBRATION and/or FLUKE 289 True-rms Industrial Logging Multimeter with TrendCapture REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: