YOKOGAWA DL2700-700822 REPAIR and YOKOGAWA DL2700-700822 CALIBRATION

 
Custom-Cal has a high success rate in the repair of the YOKOGAWA DL2700-700822. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the YOKOGAWA DL2700-700822 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope?
Shop for Comparable Products on our
 used Oscilloscope page

 
   YOKOGAWA DL2700-700822   Description / Specification:    
YOKOGAWA DL2700-700822 2 Ch 150 MHz Long Memory Digital Oscilloscope

The Yokogawa DL2700-700822 Multi-channel Long Memory Digital Oscilloscope, with a maximum record length of 4 MW, features more than just a long record length. We designed this instrument to facilitate long record measurement work. This digital oscilloscope can efficiently capture abnormal phenomena buried in long data, allowing you to search for and analyze the causes of these abnormal phenomena. We made the record length per channel as long as possible to enable you to carry out efficient troubleshooting. We also designed the instrument to measure data in at least six channels, enabling you to determine the cause and effect relationship between each signal. The instrument also has excellent zoom operability to permit analysis of captured waveforms. Specifications. Frequency Band: DC to 150 MHz. 2 input channels. Input impedance: 1 M ohm ±1.5% (approx. 16 pF). Trigger Sensitivity: 1 div p-p (DC to 150 MHz). Vertical Voltage axis sensitivity: 2 mV/div to 5 V/div. Horizontal Time axis accuracy: ±(0.01% + 500 ps), Sweep time: 2 ns/div to 50 s/div. Sampling rate; Max: 500 MS/s, Per channel: 200 MS/s. Record length; Max: 4 M words, Per channel: 2 M words. Number of channels that can be used at the max sampling rate or max record length: 1. Display, LCD: 8.4-inch TFT, color (640 x 480 dots).



 

Standard Calibration $220.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the YOKOGAWA DL2700-700822. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBc
dBc (decibels relative to the carrier) is the power ratio of a signal to a carrier signal, expressed in decibels. If the dBc figure is positive, then the relative signal strength is greater than the carrier signal strength. If the dBc figure is negative, then the relative signal strength is less than carrier signal strength.

Load Regulation
Load regulation is the capability to maintain a constant voltage (or current) level on the output channel of a power supply despite changes in the supply's load (such as a change in resistance value connected across the supply output).

Power Linearity
When changing the power level and measuring the differences (in dB) between actual and displayed power levels, the power linearity is ± half the span (in dB) between the maximum and the minimum value of all differences.

Settling Time
Settling time of an output device is the time elapsed from the application of an ideal instantaneous step input to the time at which the amplifier output has entered and remained within a specified error band, usually symmetrical about the final value.


Please contact us for your YOKOGAWA DL2700-700822 REPAIR and/or YOKOGAWA DL2700-700822 2 Ch 150 MHz Long Memory Digital Oscilloscope CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: