   NEW RIDGE TECHNOLOGIES NRT-8000   Description / Specification:    
NEW RIDGE TECHNOLOGIES NRT-8000 1527.2 to 1565.5 nm Handheld Optical Spectrum Analyzer

The New Ridge Technologies NRT-8000 is World's smallest OSA at the announcement (Oct. 1, 2013). With built-in reference for each single sweep, the NRT-8000 boasts excellent wavelength/frequency (±3.0 GHz or 0.0024nm) across the entire wavelength range. The rugged and compact design is perfect for outside plant (OSP) and military field applications. The integrated Server-Client (TCP/IP) software offers flexible remote control capabilities over the internet. The NRT-8000 is truely a universal OSA at affordable price. The NRT-8000 control software boasts the most simplified graphical user interface desgin. Without complex menu, the operator can start working on this instrument without learning curve. The control software is compatible with Windows XP, Windows 7 and Windows 8 that will meet vast majority of customers' requirements in the lab, in the systems and in the field. Specifications. Wavelength (Frequency) Coverage: 1527.2 nm to 1565.5 nm (196.3 THz to 191.5 THz). Absolute Wavelength (Frequency) Accuracy: ± 3.0 GHz (0.024nm). Optical Resolution (Line-width of Tunable Filter Shape): < 3.5 GHz (0.028nm) (Full width at half maximum (FWHM) of the tunable filter shape). Absolute Power Accuracy: ± 0.5 dB or better. Polarization Dependent Loss (PDL): < 0.4 dB. Optical Power Handling: +9 dBm (Operating Limit), +21 dBm (Damage Threshold). Optical Noise Floor Below: - 70 dBm (no input light). Optical Return Loss: > 30 dB. Scan Speed: < 0.5 second (for power and wavelength data only), < 5 seconds (for high-resolution spectrum and data). Communication Interface: USB 2.0 (USB 1.0 compatible). Weight < 2 Ib (less than 900 g).



 

Standard Calibration $475.00 *
*This is a Web introductory price for one calibration of the NEW RIDGE TECHNOLOGIES NRT-8000. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Optical Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Chirp
A change in the optical frequency caused by direct modulation of the laser. A chirp is a signal in which the frequency increases ('up-chirp') or decreases ('down-chirp') with time. In some sources, the term chirp is used interchangeably with sweep signal.

Isolation
The extent to which optical power from one signal path is prevented from reaching another signal path.

Polarization Extinction Ratio
Polarization Extinction Ratio is the ratio of optical power in the slow axis of the polarization maintaining fiber to optical power in the fast axis within a specified wavelength range.

Sidemode Suppression Ratio
Sidemode Suppression Ratio is the ratio of average signal power to the optical power of the highest sidemode within a distance from 0.1 to 6 GHz to the signal’s optical frequency, expressed in dB.

Wavelength Stability
Wavelength Stability is the change of wavelength during given time span, expressed as ± half the span between the maximum and the minimum of all actual wavelengths.


I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: