AMPROBE 30XR-A CALIBRATION and AMPROBE 30XR-A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the AMPROBE 30XR-A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Multimeter DMM?
Shop for Comparable Products on our
 used Multimeter DMM page

 
   AMPROBE 30XR-A   Description / Specification:   Spec Sheet 
AMPROBE 30XR-A Auto Ranging Digital Multimeter with Non-Contact Volt Detect

The Amprobe 30XR-A Digital Multimeter offers Voltect™ non-contact voltage technology built into the 30XR-A along with a full complement of measurement functions. Specifications. DC Voltage ranges: 200 mV, 2 V, 20 V, 200 V, 600 V. DC Voltage accuracy: all ranges: ± (1 % rdg + 1 dgt). DC Voltage resolution: 100 µV. AC Voltage (45 Hz to 500 Hz) ranges: 200 mV, 2 V, 20 V, 200 V, 600 V. AC Voltage (45 Hz to 500 Hz) accuracy: all ranges: ± (1.5 % rdg + 4 dgts). AC Voltage (45 Hz to 500 Hz) resolution: 100 µV. DC Current ranges: 200 µA, 2 mA, 20 mA, 200 mA, 10 A. DC Current accuracy: 200 µA to 200 mA ranges ± (1.5 % rdg + 1 dgt), 10 A range: ± (2.0 % rdg + 3 dgts). DC Current resolution: 0.1 µA. AC Current (45 Hz to 500 Hz) ranges: 200 µA, 2 mA, 20 mA, 200 mA, 10 A. AC Current (45 Hz to 500 Hz) accuracy: 200 µA to 200 mA ranges ± (2.0 % rdg + 4 dgts), 10A range: ± (2.5 % rdg + 4 dgts). AC Current resolution: 0.1 µA. Resistance Ranges: 200 ohm, 2 kohm, 20 kohm, 200 kohm, 2 Mohm, 20 Mohm. Resistance Accuracy: 200 ohm to 200 kohm ranges ± (1.0 % rdg + 4 dgts), 2 Mohm range ± (1.5 % rdg + 4 dgts), 20 Mohm range ± (2.0 % rdg + 5 dgts). Resistance Resolution: 100 mohm. Non-contact voltage detector (NCV) AC volts: 70 to 600 V ac. Non-contact voltage detector (NCV): Red LED and Audible Indicator. Display: 3-1/2 digit LCD, 1999 counts. Display Update Rate: 2.5/sec, nominal.



 

Standard Calibration $95.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the AMPROBE 30XR-A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Available Gain
Available Gain is the ratio, at a specific frequency, of power available from the output to the power in from the source.

Decibel (dB)
A unit of measurement of power which indicates relative power. A -10 dB means a reduction in power by 10 times, -20 dB means another 10 times or 100 times overall, -30 means another 10 times or 1000 times overall and so on.

Mismatch Uncertainty
Mismatch Uncertainty is caused by re-reflections between one device (the source) and the device that follows it (the load).

Pulse Power
Pulse Power, the energy transfer rate is averaged over the pulse width. Pulse width is considered to be the time between the 50 percent risetime/falltime amplitude points. Pulse power averages out any aberrations in the pulse envelope such as overshoot or ringing.


Please contact us for your AMPROBE 30XR-A CALIBRATION and/or AMPROBE 30XR-A Auto Ranging Digital Multimeter with Non-Contact Volt Detect REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: