Keysight (Agilent) 54510A REPAIR and Keysight (Agilent) 54510A CALIBRATION

 
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) 54510A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 54510A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope?
Shop for Comparable Products on our
 used Oscilloscope page

 
   Keysight (Agilent) 54510A   Description / Specification:    
Keysight (Agilent) 54510A 2 Ch 250 MHz Digitizing Oscilloscope

The HP 54510A is a 250 MHz, 1 GSa/s sample rate, 2-channel digitizing oscilloscope with 8 bit A/Os designed for both repetitive and single-shot signals. The HP 54510A boosts single-shot performance to 250 MHz by introducing the first 1 Gigasample-per-second portable oscilloscope.. Like other members of the HP 54500 family, the HP 54510A has all of the digitizing advantages of oscilloscopes that are much higher in price. Its high repetitive / single-shot bandwidth, ease of use, HP-IB programmability, and HP 54500 family general-purpose features make it a powerful tool for both manual and automated test applications. Specifications. Bandwidth: dc to 250 MHz (-3 dB), (300 MHz repetitive mode typical). Rise time: 1.4 ns. Number of channels: 2 (simultaneous). Vertical sensitivity range: 1 mV/div to 5 V/div. Vertical gain Accuracy: ± 1.25% of full scale. Vertical resolution: 8 bits over eight divisions (± 0.4%), 10 bits wl averaging (± 01 %). Maximum sample rate: 1 GSa/s. Waveform record length: 8001 points (real-time), 501 points (repetitive). Maximum input voltage: 1 M-ohm: ± 250 V [dc + peak ac < 10 kHz)], 50 ohm: 5 V rms. Time base range: 1 ns/dlV to 5 s/div. Maximum time base resolution: 20 ps.



 

Standard Calibration $325.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 54510A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Crest Factor
Crest factor or peak-to-average ratio (PAR) is a measurement of a waveform, calculated from the peak amplitude of the waveform divided by the RMS value of the waveform

Linearity
Linearity is the relative difference between the displayed power ratio, Dx/D0, and the actual (true) power ratio Px/P0 caused by changing the displayed power level from the reference level, D0, to an arbitrary displayed level, Dx.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.

Sensitivity
Sensitivity is the minimum magnitude of input signal required to produce a specified output signal having a specified signal-to-noise ratio, or other specified criteria.


Please contact us for your Keysight (Agilent) 54510A REPAIR and/or Keysight (Agilent) 54510A 2 Ch 250 MHz Digitizing Oscilloscope CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: