Keysight (Agilent) 54522C CALIBRATION and Keysight (Agilent) 54522C REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 54522C Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope?
Shop for Comparable Products on our
 used Oscilloscope page

 
   Keysight (Agilent) 54522C   Description / Specification:    
Keysight (Agilent) 54522C 2 Ch 500 MHz Digitizing Oscilloscope

The HP 54522A is a 500 MHz, 2 GSa/s sample rate, 2-channel digitizing oscilloscope. It has all of the features that you would expect in a scope plus more. Use sequential single-shot when you need to capture successive single-shot events without capturing the dead time in between. It is a great tool for applications such as pulsed laser research, high-energy physics, and pulse echo. Use glitch trigger to find the causes of anomalies in circuit operation. Trigger on hard-to-see narrow glitches down to 1 ns wide. Waveforms can be saved and time-stamped upon failure of either wave form compare or limit test. Up to 665 failures of 500 points each can be stored in multiple memory and sent to a printer, plotter, or a computer via HP-IB. Specifications. Repetitive Bandwidth: 500 MHz (equivalent time). Real-time bandwidth: 500 MHz (all channels on). Number of channels (all are simultaneous acquisition): 2. Vertical sensitivity range: 1 mV/div to 5 V/div. Vertical dc gain Accuracy: ± 1.25% of full scale. Vertical resolution: 8 bits (10 bits via HP-IB with averaging). Maximum sample rate (Real time mode): 1 GSa/s (1 channel on), 500 MSa/s (2 channels on). Maximum sample rate (Repetitive mode): 1 GSa/s. Waveform record length: 32,768 points (real-time), 501 points (repetitive). Maximum input: 1 M-ohm: ± 250 V (dc + ac) [ac<10 kHz], 50 ohm: 5 V rms. Time base range: 500 ps/div to 5 s/div. Resolution: 10 ps. Trigger Pulse width (minimum) 1 ns. Color Display. Opt 001 Telecommunications Mask Test Software.



 

Standard Calibration $325.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 54522C. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Averaging
Averaging is a mathematical process to reduce the variation in a measurement by summing the data points from multiple measurements and dividing by the number of points summed.

Fall Time
Fall time is the time required for the amplitude of a pulse to decrease (fall) from a specified value (usually 90 percent of the peak value exclusive of overshoot or undershoot) to another specified value (usually 10 percent of the maximum value exclusive of overshoot or undershoot).

Noise Density
Noise Density is the amount of noise within a defined bandwidth, usually normalized to 1 Hz.

Resolution Bandwidth (RBW)
Resolution Bandwidth (RBW) is the minimum bandwidth over which you can separate two signals and still see them.


Please contact us for your Keysight (Agilent) 54522C CALIBRATION and/or Keysight (Agilent) 54522C 2 Ch 500 MHz Digitizing Oscilloscope REPAIR

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: