Keysight (Agilent) 54601A CALIBRATION and Keysight (Agilent) 54601A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 54601A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope?
Shop for Comparable Products on our
 used Oscilloscope page

 
   Keysight (Agilent) 54601A   Description / Specification:    
Keysight (Agilent) 54601A 4 Ch 100 MHz Digital Oscilloscope

The HP 54601A four-channel oscilloscope provides powerful digital features, such as pre-trigger viewing, waveform storage, and measurement automation. It captures repetitive signals at up to 10 GSa/sec (single shot phenomena at up to 20 MSa/sec) giving a clear and accurate display of the most troublesome signals. The display update rate of over one million points per second provides a display with unprecedented interactivity. Specifications. Bandwidth ( -3dB): dc to 100 MHz. Channels: 4. Input voltage ranges Channels 1 and 2: 2 mV/div to 5 V/div. Input voltage ranges Channels 3 and 4: 0.1 and 0.5 V/div. Accuracy: ± 1.5%. Vernier accuracy: Fully calibrated ± 3%. Rise time <3.5 ns (calculated). Coupling: dc. ac, and ground. Maximum input: 400 V (dc + peak ac). Sweep speeds, main and delayed: 5 s/div to 2 ns/div/1 ns/div. Accuracy: ± 0.01%. Resolution: 100 ps. Vernier accuracy: ± 0.05%. Trigger Sensitivity all channels: dc to 25 MHz, 0.35 div or 3.5 mV. Max sample rate: 10/GSa/s for repetitive signals, 20 MSa/s single shot. Record length: 4,000 points (2,000 points single shot). Max update rate: 1,000,000 points/s.



 

Standard Calibration $350.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 54601A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Available Gain
Available Gain is the ratio, at a specific frequency, of power available from the output to the power in from the source.

Decibel (dB)
A unit of measurement of power which indicates relative power. A -10 dB means a reduction in power by 10 times, -20 dB means another 10 times or 100 times overall, -30 means another 10 times or 1000 times overall and so on.

Mismatch Uncertainty
Mismatch Uncertainty is caused by re-reflections between one device (the source) and the device that follows it (the load).

Pulse Power
Pulse Power, the energy transfer rate is averaged over the pulse width. Pulse width is considered to be the time between the 50 percent risetime/falltime amplitude points. Pulse power averages out any aberrations in the pulse envelope such as overshoot or ringing.


Please contact us for your Keysight (Agilent) 54601A CALIBRATION and/or Keysight (Agilent) 54601A 4 Ch 100 MHz Digital Oscilloscope REPAIR

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: