Keysight (Agilent) 54602B REPAIR and Keysight (Agilent) 54602B CALIBRATION

 
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) 54602B. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 54602B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope?
Shop for Comparable Products on our
 used Oscilloscope page

 
   Keysight (Agilent) 54602B   Description / Specification:    
Keysight (Agilent) 54602B 4 Ch 150 MHz Digital Oscilloscope

The HP 54602B four-channel oscilloscope provides powerful digital features, such as pre-trigger viewing, waveform storage, and measurement automation. It captures repetitive signals at up to 10 GSa/sec (single shot phenomena at up to 20 MSa/sec) giving a clear and accurate display of the most troublesome signals. The display update rate of over one and a half million points per second provides a display with unprecedented interactivity. Bright, crisp displays for the most demanding signals at all sweep speeds and delayed sweep magnifications. Storage for glitch and transient analys is is as simple as pressing a button. Pretrigger viewing lets you view even ts that an analog scope would miss. Specifications. Bandwidth Ch 1 & 2: dc to 150 MHz, 100 MHz @ 1, 2 & 5 mV/div. Channels: 4. Sensitivity (per division) Ch 1 & 2: 2 mV/div to 5 V/div. Sensitivity (per division) Ch 3 & 4: 0.1 V/div to 0.5 V/div. Accuracy: ± 1.5%. Vernier accuracy: ± 3%. Rise time Ch 1 & 2: 2.3 ns (calculated). Rise time Ch 3 & 4: 1.4 ns (calculated). Input R & C: 1 M-ohm, = 13 pf. Maximum input dc + peak ac: 400 V. Sweep speed: 5 s/div to 2 ns/div. Accuracy: ± 0.01%. Resolution: 100 ps. Vernier accuracy: ± 0.05%. Max sample rate: 20 MSa/s. Record length (pts vectors off/on): 4,000/2,000. Trigger Sensitivity all channels: dc to 25 MHz, 0.35 div or 3.5 mV. Opt 005 Enhanced Video Trigger.



 

Standard Calibration $350.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 54602B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Carrier Wave (CW)
Carrier Wave or Continuous Wave is a sinusoidal signal without modulation.

Harmonic
A harmonic of a wave is a component frequency of the signal that is an integer multiple of the fundamental frequency, i.e. if the fundamental frequency is f, the harmonics have frequencies 2f, 3f, 4f, . . . etc.

Noise Floor
Noise floor is the measure of the signal created from the sum of all the noise sources and unwanted signals within a measurement system.

Ripple
Ripple is the small unwanted residual periodic variation of the direct current (dc) output


Please contact us for your Keysight (Agilent) 54602B REPAIR and/or Keysight (Agilent) 54602B 4 Ch 150 MHz Digital Oscilloscope CALIBRATION

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: