Keysight (Agilent) 8719D CALIBRATION and Keysight (Agilent) 8719D REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 8719D Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Network Analyzer, SNA, VNA?
Shop for Comparable Products on our
 used Network Analyzer, SNA, VNA page or new Network Analyzer, SNA, VNA page

 
   Keysight (Agilent) 8719D   Description / Specification:    
Keysight (Agilent) 8719D Vector Network Analyzer

The HP 8719D vector network analyzers offer builtin source, receiver, and solid-state switching S-parameter test set covering frequencies from 50 MHz to 13.5 GHz. They have a fast source that is fully synthesized, in both swept or stepped modes, with stability and accuracy within 10 ppm (typical). Frequency resolution is 1 Hz standard for accurate measurements of narrowband or long-delay devices. The tuned receivers with variable bandwidth IF filters provide up to 105 dB of dynamic range. A solid-state switching test set provides continuous updating of all four S-parameters as required for two-port error correction. Frequency Range: 50 MHz to 13.5 GHz. Frequency Resolution: 1 Hz. Frequency Accuracy: 10 ppm. Maximum Source Power: +5 dBm (std), +10 dBm (Option 007). Minimum Source Power: -70 dBm (std), -65 dBm (Option 007). Power Resolution: 0.01 dB. Power Flatness: ± 1.5 dB. Power Sweep Range: 20 dB. System Dynamic Range (>2 GHz): 100 dB, 105 dB (Option 007). Test Port Connector 3.5 mm. Options: 007, Mechanical Transfer Switch. 010, Time Domain Capability. 012, Direct Sampler Access. 085, High-Power Test Set. 089, Frequency Offset Mode. 1D5, High-Stability Frequency Reference. 400, Four-Sampler Test Set.



 

Standard Calibration $675.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 8719D. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBc
dBc (decibels relative to the carrier) is the power ratio of a signal to a carrier signal, expressed in decibels. If the dBc figure is positive, then the relative signal strength is greater than the carrier signal strength. If the dBc figure is negative, then the relative signal strength is less than carrier signal strength.

Noise Density
Noise Density is the amount of noise within a defined bandwidth, usually normalized to 1 Hz.

Spurious Signals
Spurious signals are undesired signals. They can be considered in two classes. They can be stationary; their frequency and amplitude do not change significantly, or non-stationary, where the frequency and/or amplitude change significantly over short time periods.


Please contact us for your Keysight (Agilent) 8719D CALIBRATION and/or Keysight (Agilent) 8719D Vector Network Analyzer REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: