Keysight (Agilent) DSO6014A REPAIR and Keysight (Agilent) DSO6014A CALIBRATION

 
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) DSO6014A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) DSO6014A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope?
Shop for Comparable Products on our
 used Oscilloscope page

 
   Keysight (Agilent) DSO6014A (DS06014A)   Description / Specification:    
Keysight (Agilent) DSO6014A 4 Ch 100 MHz InfiniiVision Oscilloscope

The Agilent DSO6014A InfiniiVision 100 MHz, 4 analog channel oscilloscope is equipped with a 6.3” XGA LCD display, comes in a whisper-quiet package that weighs only 11 pounds. The InfiniiVision 6000 Series shows jitter, infrequent events, and subtle signal detail that other scopes miss. Turn knobs and the instrument responds instantly and effortlessly. InfiniiVision scopes incorporate acquisition memory, waveform processing, and display memory in an advanced 0.13 µ ASIC. This patented 3rd generation technology, known as MegaZoom III, delivers up to 100,000 waveforms (acquisitions) per second with responsive deep memory always available. Specifications. Bandwidth: 100 MHz. Sample rate: 2 GSa/sec each channel. Maximum memory depth 2 channels/4 channels: 8 Mpts/4 Mpts. Input channels: 4 analog. Vertical resolution. 8 bits. Peak detection: 1-ns peak detect. Averaging Selectable from: 2, 4, 8, 16, 32, 64 ... to 65536. High resolution mode: Average mode with avg = 1, 12 bits of resolution when >=10 µs/div @ 4 GSa/s or >=20 µs/div @ 2 GSa/s. Vertical system scope channels; Scope channels: Ch 1, 2, 3 and 4 simultaneous acquisition. Bandwidth (–3dB): DC to 100 MHz. Calculated rise time (=0.35/bandwidth): 3.5 nsec. Single-shot bandwidth: 100 MHz. Range: 1 mV/div to 5 V/div (1 Mohm). Maximum input: CAT I 300 Vrms, 400 Vpk; transient overvoltage 1.6 kVpk. Horizontal; Range: 5 nsec/div to 50 sec/div. Resolution: 2.5 psec. Time scale accuracy: <= ± (15 + 2*(instrument age in years)) ppm.



 

Standard Calibration $425.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) DSO6014A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Bandwidth
Bandwidth is the difference between the upper and lower frequencies in a contiguous set of frequencies within which a component, link or network will operate.

Frequency Span
Frequency Span specifies the range between the start and stop frequencies, also referred to as bandwidth

Noise Figure
Noise Figure the ratio of the signal-to-noise power ratio at the input to the signal-to-noise power ratio at the output.

Ringing
Ringing is an unwanted oscillation of a voltage or current.


Please contact us for your Keysight (Agilent) DSO6014A REPAIR and/or Keysight (Agilent) DSO6014A 4 Ch 100 MHz InfiniiVision Oscilloscope CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: