FLUKE 11 CALIBRATION and FLUKE 11 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the FLUKE 11 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Multimeter DMM?
Shop for Comparable Products on our
 used Multimeter DMM page

 
   FLUKE 11   Description / Specification:    
FLUKE 11 Handheld Digital Multimeter

The Fluke 11 Digital Multimeter is designed to support first level electrical and electronic troubleshooting. Their compact design, slide-switch and pushbutton controls allow true one-hand operation. V Chek simplifies safe power source and supply measurement. When measuring ohms/continuity with more than 4.5 volts present across the input jacks (intentional or not), the meter automatically switches to measuring ac or dc volts, whichever is greater. Input impedance is approximately 2 k-ohm, helping determine if voltage is from leakage or a hard connection. Overload protection is provided if the circuit is checked in ohms mode. Features. 4000 Count Digital Display. Diode Test. Fast Continuity Beeper. Sleep Mode. Specifications. VDC Range: 4.000 to 600 V. VDC Best Accuracy: ±(0.9% + 1). VDC Resolution: 1 mV. VAC Range: 4.000 to 600 V. VAC Best Accuracy: ±(1.9% + 3). VAC Resolution: 1 mV. Resistance Range: 400 ohm to 40 M-ohm. Resistance Best Accuracy: ±(0.9% + 1). Resistance Resolution: 0.1 ohm. Capacitance Range: 1.000 to 10,000 uF. Capacitance Best Accuracy: ±(1.9% + 2). Capacitance Resolution: 0.001 uF.



 

Standard Calibration $65.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the FLUKE 11. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Channel Bandwidth
Channel Bandwidth is the bandwidth over which power is measured. This is usually the bandwidth in which almost all of the power of a signal is contained.

Jitter
Jitter in technical terms is the deviation in or displacement of some aspect of the pulses in a high-frequency digital signal. Jitter is the time variation of a periodic signal in electronics and telecommunications, often in relation to a reference clock source. Jitter may be observed in characteristics such as the frequency of successive pulses, the signal amplitude, or phase of periodic signals. Jitter is a significant, and usually undesired, factor in the design of almost all communications links (e.g., USB, PCI-e, SATA, OC-48). In clock recovery applications it is called timing jitter.

Overshoot
Overshoot is the distortion that follows a major transition; the difference between the peak power point and the pulse-top amplitude computed as a percentage of the pulse-top amplitude.

Rise Time
Rise time refers to the time required for a signal to change from a specified low value to a specified high value, usually 10 and 90 percent of pulse-top amplitude (vertical display is linear power).


Please contact us for your FLUKE 11 CALIBRATION and/or FLUKE 11 Handheld Digital Multimeter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: