FLUKE 112 CALIBRATION and FLUKE 112 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the FLUKE 112 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Multimeter DMM?
Shop for Comparable Products on our
 used Multimeter DMM page

 
   FLUKE 112   Description / Specification:    
FLUKE 112 Handheld True RMS Digital Multimeter

The Fluke 112 true-rms multimeter has all the basic measurement features and functions needed for every day tasks. Their simplicity and compact design, make them perfect for quick verifications for field service and contractor use. Features. 600 V measurement range. True-rms for accurate measurements. 10 amps continuous. Resistance and continuity. Frequency and capacitance. Min/Max to record signal fluctuations. Backlight for work in dim areas. Meets measurement CAT III 600 V safety standards. Specifications. V DC Range: 6000 mV, 6.000 V, 60.00 V, 600.0 V. V DC Best Accuracy: ± 0.7 % of reading. V AC Range: 6000 mV, 6.000 V, 60.00 V, 600.0 V. V AC Best Accuracy: ± 1.0 % of reading. A DC Range: 6.000 A, 10.00 A. A DC Best Accuracy: ± 1.0 % of reading. A AC Range: 10.00 A. A AC Best Accuracy: ± 1.5 % of reading. Resistance Range: 600.0 ohm, 6.000 kohm, 60.00 kohm, 600.0 kohm, 6.000 Mohm, 40.00 Mohm. Resistance Best Accuracy: ± 1.5 % of reading. Capacitance Range: 1000 nF, 10.00 µF, 100.0 µF, 9999 µF. Capacitance Best Accuracy: ± 1.9 % of reading. Frequency Range (Voltage frequency is specified from 5 Hz to 50 kHz. Current Frequency is specified from 50 Hz to 5 kHz.): 99.99 Hz, 999.9 Hz, 9.999 Hz, 50.00 kHz. Frequency Best Accuracy: ± 0.1 % of reading.



 

Standard Calibration $65.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the FLUKE 112. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBc
dBc (decibels relative to the carrier) is the power ratio of a signal to a carrier signal, expressed in decibels. If the dBc figure is positive, then the relative signal strength is greater than the carrier signal strength. If the dBc figure is negative, then the relative signal strength is less than carrier signal strength.

Load Regulation
Load regulation is the capability to maintain a constant voltage (or current) level on the output channel of a power supply despite changes in the supply's load (such as a change in resistance value connected across the supply output).

Power Linearity
When changing the power level and measuring the differences (in dB) between actual and displayed power levels, the power linearity is ± half the span (in dB) between the maximum and the minimum value of all differences.

Settling Time
Settling time of an output device is the time elapsed from the application of an ideal instantaneous step input to the time at which the amplifier output has entered and remained within a specified error band, usually symmetrical about the final value.


Please contact us for your FLUKE 112 CALIBRATION and/or FLUKE 112 Handheld True RMS Digital Multimeter REPAIR

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: