FLUKE 8062A CALIBRATION and FLUKE 8062A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the FLUKE 8062A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Multimeter DMM?
Shop for Comparable Products on our
 used Multimeter DMM page

 
   FLUKE 8062A   Description / Specification:    
FLUKE 8062A 4 1/2 Digit TRMS Digital Multimeter

The Fluke 8062A 4 1/2-digit DMM offers more measurement capabilities than many bench/portable models. Well suited for engineers and technicians working in audio, video, telecommunications, or computer technology, both meters combine precision and accuracy with a wealth of features to fit nearly every application. True-rms ac voltage and current measurement. Fast audible-visual continuity tests. Relative Reference (offset). When measuring ohms with the 8062A the relative reference function displays only the difference between a stored reference value and a measured value, even if the range was changed between readings. Relative mode works in all functions and ranges. Specifications. VDC Range: 200 mV - 1000 V. VDC Best Accuracy: ±(0.05% + 2). VDC Resolution: 10 uV. VAC (True-RMS, AC Coupled) Range: 200 mV - 1000 V. VAC Best Accuracy: ±(0.5% + 10). VDC Resolution: 10 uV. ADC Range: 200 uA - 2000 mA. ADC Best Accuracy: ±(0.3% + 2). ADC Resolution: 0.01 uA. AAC (True-RMS) Range: 200 uA - 2000 mA. AAC Best Accuracy: ±(0.75% + 10). AAC Resolution: 0.01 uA. Resistance Range: 200 ohm - 300 M-ohm. Resistance Best Accuracy: ±(0.1% + 2). Resistance Resolution: 0.01 ohm.



 

Standard Calibration $70.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the FLUKE 8062A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Dynamic range
Dynamic range the ratio of a specified maximum level of a parameter, such as power, current, voltage or frequency, to the minimum detectable value of that parameter.

Modulation
Modulation is the process by which the characteristic of one wave (the carrier) is modified by another.

Repeatability
Repeatability is the variation in a number of repeated measured quantities when measurement conditions are changed and restored. The value corresponds to half the spread between the minimum and maximum value measured.


Please contact us for your FLUKE 8062A CALIBRATION and/or FLUKE 8062A 4 1/2 Digit TRMS Digital Multimeter REPAIR

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: