INSTEK GFG-8216A REPAIR and INSTEK GFG-8216A CALIBRATION

 
Custom-Cal has a high success rate in the repair of the INSTEK GFG-8216A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the INSTEK GFG-8216A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Function Generator?
Shop for Comparable Products on our
 used Function Generator page or new Function Generator page

 
   INSTEK GFG-8216A   Description / Specification:   Spec Sheet 
INSTEK GFG-8216A 3 MHz Function Generator w/Counter

The Instek GFG-8216A 3 Mhz Function Generator With Counter output waveforms are Sine, Triangle, Square, Ramp, TTL and CMOS. It has External Voltage Controlled Frequency (VCF) Function, Duty Cycle Control with Signal Inversion Capability, Variable DC Offset Control and a Two-Step (-20dBx2) and Variable attenuator. The Instek GFG-8216A has a built-in 6 Digit Counter with INT/EXT Function up to 150 MHz. Specifications. Frequency Range: 0.3 Hz to 3 MHz (7 Range). Amplitude: > 10 Vpp (into 50 ohm load). Impedance: 50 ohm ±10%. Attenuator: -20 dB ±1 dB x 2. DC Offset: <-5V to >5V (into 50 ohm load). Duty Control: 80% : 20% : 80% to 1MHz Continue variable. Sine Wave Distortion: <=1%, 0.3 Hz to 200 kHz THD <=35 dB below fundamental in all range (Specification applied from MAX. to 1/10 level). Sine Wave Flatness: < 0.3 dB, 0.3 Hz to 300kHz, < 0.5 dB, 300 kHz to 3 MHz. Triangle Wave Linear: >= 98% 0.3 Hz to 100 kHz, 95% 100 kHz to 3 MHz. Square Wave Symmetry: ±2%, 0.3 Hz to 100 kHz. Square Wave Rise or Fall Time: <= 100 nS at maximum output (into 50 ohm load). Frequency Counter Range: 0.3 Hz to 3 MHz (5 Hz to 150 MHz EXT.) Frequency Counter Accuracy: Time base accuracy 1 count.



 

Standard Calibration $95.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the INSTEK GFG-8216A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Crest Factor
Crest factor or peak-to-average ratio (PAR) is a measurement of a waveform, calculated from the peak amplitude of the waveform divided by the RMS value of the waveform

Linearity
Linearity is the relative difference between the displayed power ratio, Dx/D0, and the actual (true) power ratio Px/P0 caused by changing the displayed power level from the reference level, D0, to an arbitrary displayed level, Dx.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.

Sensitivity
Sensitivity is the minimum magnitude of input signal required to produce a specified output signal having a specified signal-to-noise ratio, or other specified criteria.


Please contact us for your INSTEK GFG-8216A REPAIR and/or INSTEK GFG-8216A 3 MHz Function Generator w/Counter CALIBRATION

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: