BK PRECISION 325 CALIBRATION and BK PRECISION 325 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the BK PRECISION 325 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   BK PRECISION 325   Description / Specification:   Spec Sheet 
BK PRECISION 325 AC/DC True RMS Power Clamp Meter

The B&K Precision 325 AC/DC True RMS Power Clamp Meter provides safe, non-invasive measurements of up to 400KW, 400 Amps AC (± 2%+10 dgt), and measures up to 600 Volts AC (±1%+10 dgt), and up to 600 Volts DC (±1.5%+10 dgt) utilizing the a pair of standard test leads. It provides the ability to measure up to 4000 ohms of resistance (±1%+5 dgt) and 40 ohms of audible continuity. The unit’s Data Hold feature allows the user to freeze the LCD display reading. Other features include a front panel 3-3/4 digit LCD display, automatic range selection, over-range and low battery indicators, automatic power off after 30 minutes, and a maximum jaw opening of 1.37” inches (35mm). Specifications. DC Current Range: 400A, 600A. AC Current (True RMS : From 10% to 100% of Range) Range: 400A, 600A. DC Voltage Range: 400V, 600V. AC Voltage (True RMS : From 10% to 100% of Range) Range: 400V, 600V. AC + DC WATT Range: 40 KW, 400 KW. Resistance Range: 4000 ohm. Frequency Range: 4 kHz, 40 kHz, 400 kHz.



 

Standard Calibration $80.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the BK PRECISION 325. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Crest Factor
Crest factor or peak-to-average ratio (PAR) is a measurement of a waveform, calculated from the peak amplitude of the waveform divided by the RMS value of the waveform

Linearity
Linearity is the relative difference between the displayed power ratio, Dx/D0, and the actual (true) power ratio Px/P0 caused by changing the displayed power level from the reference level, D0, to an arbitrary displayed level, Dx.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.

Sensitivity
Sensitivity is the minimum magnitude of input signal required to produce a specified output signal having a specified signal-to-noise ratio, or other specified criteria.


Please contact us for your BK PRECISION 325 CALIBRATION and/or BK PRECISION 325 AC/DC True RMS Power Clamp Meter REPAIR

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: