BK PRECISION 889B CALIBRATION and BK PRECISION 889B REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the BK PRECISION 889B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   BK PRECISION 889B   Description / Specification:   Spec Sheet 
BK PRECISION 889B 200 kHz Bench LCR/ESR Meter with Component Tester

The B&K Precision 889B synthesized in-circuit bench LCR/ESR meter is a high accuracy test instrument used for measuring inductors, capacitors and resistors with a basic accuracy of 0.1%. Also, with the built-in functions of DC/AC Voltage/Current measurements and Diode/Audible Continuity checks. Measurement parameters include; Z, L, C, DCR, ESR, D, Q, ACV, DCV, ACA, DCA and Ø. Specifications: Test Frequencies: 100 Hz, 120 Hz, 1 kHz, 10 kHz, 100 kHz, 200 kHz. Frequency Accuracy: ± 0.1%. Test Levels: 1 Vrms, 0.25 Vrms, 0.05 Vrms, 1 Vdc (for DCR). Level Accuracy: ± 10%. Output Impedance: 100 ohm, ± 5%. Impedance (Z) Frequency Range: DCR, 100 Hz, 120 Hz, 1 kHz, 10 kHz (Minimum 0.1 ohm to 20 M-ohm), 100 kHz, 200 kHz (Minimum 0.1 ohm to 10 M-ohm). Capacitance (C) Frequency Range (min to max): 100 Hz (15.91 mF to 79.57 pF), 120 Hz (13.26 mF to 66.31 pF), 1 kHz (1.591 mF to 7.957 pF), 10 kHz (159.1 µF to 0.795 pF), 100 kHz (15.91 µF to 0.159 pF), 200 kHz (7.957 µF to 0.079 pF). Inductance (L) Frequency Range (min to max): 100 Hz (31.83 kH to 159.1 µH), 120 Hz (26.52 kH to 132.6 µHF), 1 kHz (31.83 kH to 15.91 µH), 10 kHz (318.3 H to 1.591 µH), 100 kHz (31.83 H to 0.159 µH), 200 kHz (15.91 H to 0.079 µH). Dual LCD display.



 

Standard Calibration $135.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the BK PRECISION 889B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Clipping
Clipping is the limiting of a signal so that it never exceeds some threshold.

Line Regulation
Line regulation is the capability to maintain a constant output voltage level on the output channel of a power supply despite changes to the input voltage level.

Peak Envelope Power
Peak envelope power is the maximum value of the envelope power. Envelope power is measured by making the averaging time much less than 1/fm where fm is the maximum frequency component of the modulation waveform. The averaging time is therefore limited on both ends: (1) it must be small compared to the period of the highest modulation frequency, and (2) it must be large enough to be many RF cycles long.

RMS
RMS or root mean square is a statistical measure of the magnitude of a varying quantity


Please contact us for your BK PRECISION 889B CALIBRATION and/or BK PRECISION 889B 200 kHz Bench LCR/ESR Meter with Component Tester REPAIR

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: