BK PRECISION 9130 CALIBRATION and BK PRECISION 9130 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the BK PRECISION 9130 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another DC Power Supply?
Shop for Comparable Products on our
 used DC Power Supply page

 
   BK PRECISION 9130   Description / Specification:    
BK PRECISION 9130 Triple Output DC Power Supply

The B&K Precision 9130 is a fully programmable triple Output DC Power Supply delivering 0-30V/0-3A on 2 outputs and 0-5V/0-3A on 1 output. Each output is fully floating and outputs can be adjusted independently or connected in series or parallel to produce higher voltages or currents. The front panel keys and the control knob provide a convenient means to adjust the voltage and current of a selected output; enable or disable parallel or series tracking mode; store and recall operating states or enable/disable individual outputs. The BK 9130 is ideally suited for applications in Electronic Test, Production and Service, where multiple independent DC supplies are required and bench space is at a premium. Key Features; 3 independent, fully programmable and electrically isolated outputs. Series or parallel operation. Display Voltage and Current for of all 3 channels simultaneously. Over Current (OCP) and Over Temperature (OHT) protection. Low ripple and low noise. SCPI compatible command set, communicate via USB or RS232 port. 50 memory locations for instrument state storage & recall. Specifications. Voltage: 0 to 30 V x 2, 0 to 5 V x 1. Current: 0 to 3 A x 2, 0 to 3 A x 1. Load Regulation ±(%of output+offset): <= 0.01%+3 mV (Voltage), <= 0.01%+3 mA (Current). Line Regulation ±(%of output+offset): <= 0.01%+3 mV (Voltage), <= 0.1%+3 mA (Current). Ripple Voltage: <=1 mVrms/3 mVp-p. Noise Voltage: <= 3 mVrms.



 

Standard Calibration $135.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the BK PRECISION 9130. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Channel Bandwidth
Channel Bandwidth is the bandwidth over which power is measured. This is usually the bandwidth in which almost all of the power of a signal is contained.

Jitter
Jitter in technical terms is the deviation in or displacement of some aspect of the pulses in a high-frequency digital signal. Jitter is the time variation of a periodic signal in electronics and telecommunications, often in relation to a reference clock source. Jitter may be observed in characteristics such as the frequency of successive pulses, the signal amplitude, or phase of periodic signals. Jitter is a significant, and usually undesired, factor in the design of almost all communications links (e.g., USB, PCI-e, SATA, OC-48). In clock recovery applications it is called timing jitter.

Overshoot
Overshoot is the distortion that follows a major transition; the difference between the peak power point and the pulse-top amplitude computed as a percentage of the pulse-top amplitude.

Rise Time
Rise time refers to the time required for a signal to change from a specified low value to a specified high value, usually 10 and 90 percent of pulse-top amplitude (vertical display is linear power).


Please contact us for your BK PRECISION 9130 CALIBRATION and/or BK PRECISION 9130 Triple Output DC Power Supply REPAIR

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: