TEST PRODUCTS INTERNATIONAL 460 REPAIR and TEST PRODUCTS INTERNATIONAL 460 CALIBRATION

 
Custom-Cal has a high success rate in the repair of the TEST PRODUCTS INTERNATIONAL 460. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the TEST PRODUCTS INTERNATIONAL 460 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope?
Shop for Comparable Products on our
 used Oscilloscope page

 
   TEST PRODUCTS INTERNATIONAL 460   Description / Specification:    
TEST PRODUCTS INTERNATIONAL 460 20 MHz Hand Held Oscilloscope

The TPI 460 20 MHz hand held oscilloscope features a 3” x 3” cold cathode fluorescent display providing test data in a clear easy to see format. The cursor readout function allows the width and amplitude of a signal to be measured precisely instead of trying to figure it out manually. It includes a 4,000 count true RMS DMM, CACV, DCV ohms and continuity buzzer, optional adapters needed for current measurement. Specifications. Bandwidth: 20 MHz w/SP60B 10:1 Probe, 10 MHz w/Shielded Test Leads. Sample Rate Real Time: 25 Megasamples per Second up to 2 MHz; Equivalent Time 500 Megasamples per Second > 2 MHz. Sensitivity: 50 mV to 200 V/div 1,2,5 Sequence. Coupling: AC, DC, GND. Resolution: 8 bits. Accuracy: ± (3% + 0.05 range/div). Horizontal Samples per Division: 25. Accuracy Equivalent Time: ± (0.5% + 0.08 time/div). Accuracy Real Time: ± (0.1% + 0.04 time/div). True RMS DMM. DCV (CH1, CH2): 400mV, 4, 40, 400, 600V. DCV Basic Accuracy: ± (0.5% + 5 digits). ACV (CH1, CH2): 400mV, 4, 40, 400, 600V. ACV Basic Accuracy: ± (1% + 10 digits). Frequency (CH1, CH2): 1 Hz to 20 MHz. Frequency Basic Accuracy: ± (0.5% + 5 digits). Ohm (CH1 only): 400, 4k, 40k, 400k, 4M, 20M. Ohm Basic Accuracy: ± (0.5% + 5 digits). Continuity (CH1 only): Sounds < 0.1k ohm, ± (2% + 5 digits).



 

Standard Calibration $80.00 *
*This is a Web introductory price for one calibration of the TEST PRODUCTS INTERNATIONAL 460. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Clipping
Clipping is the limiting of a signal so that it never exceeds some threshold.

Line Regulation
Line regulation is the capability to maintain a constant output voltage level on the output channel of a power supply despite changes to the input voltage level.

Peak Envelope Power
Peak envelope power is the maximum value of the envelope power. Envelope power is measured by making the averaging time much less than 1/fm where fm is the maximum frequency component of the modulation waveform. The averaging time is therefore limited on both ends: (1) it must be small compared to the period of the highest modulation frequency, and (2) it must be large enough to be many RF cycles long.

RMS
RMS or root mean square is a statistical measure of the magnitude of a varying quantity


Please contact us for your TEST PRODUCTS INTERNATIONAL 460 REPAIR and/or TEST PRODUCTS INTERNATIONAL 460 20 MHz Hand Held Oscilloscope CALIBRATION

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: