SORENSEN DCS55-55E REPAIR and CALIBRATION

 
Custom-Cal has a high success rate in the repair of the SORENSEN DCS55-55E. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another DC Power Supply?
Shop for Comparable Products on our
 used DC Power Supply page

 
   SORENSEN DCS55-55E   Description / Specification:    
SORENSEN DCS55-55E 55V 55A Single Output DC Power Supply

The Sorensen DCS55-55E DC System Power Supply is a 3000-watt supply designed to provide highly stable, continuously variable output voltage and current for a broad range of development, system, and burn-in applications. The DCS-E Series employs high frequency switching regulator technology to achieve high power density and small package size. Features. Simultaneous digital display of both DC output voltage and current. Ten-turn potentiometer voltage and current controls permit high resolution setting of the output voltage and current from zero to the model-rated output. Front panel push button control of Output Standby Mode, OVP reset, Remote/Local Programming Mode selection, and preview of voltage, current, or OVP setpoints. External indicator signals for Remote Monitoring of OVP Status, Local/Remote Programming Status, Thermal Shutdown, and Output Voltage and Current. Current or Voltage Mode operation with Automatic Mode Crossover to respond to varying load requirements. Flexible output configuration where multiple units can be connected in series or in parallel to provide increased voltage or increased current. Remote Sensing to compensate for losses in power leads up to 1V per lead. Adjustable Over Voltage Protection (OVP). External Shutdown using AC, DC, or TTL compatible signals (positive or negative logic). Remote Voltage, Current Limit, and OVP Programming with selectable programming ranges. Specifications. Output Voltage: 0 to 55 V. Output Current: 0 to 50 A. Output Power: 3025 W. Line Regulation Voltage: 55 mV. Line Regulation Current: 55 mA. Load Regulation Voltage: 55 mV. Load Regulation Current: 55 mA. Meter Accuracy Voltage: 0.65 V. Meter Accuracy Current: 0.65 A. OVP Adjustment Range: 2.75 to 60.5 V. Output Noise and Ripple (V) (20 Hz - 20 MHz): Rms 20 mV, p-p 100 mV. Analog Programming Linearity Voltage: 550 mV. Analog Programming Linearity Current: 550 mA. Stability Voltage: 27.5 mV. Stability Current: 27.5 mA. Temperature Coefficient Voltage: 11 mV/°C. Temperature Coefficient Current: 16.5 mA/°C.



 

Standard Calibration $185.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the SORENSEN DCS55-55E. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Averaging
Averaging is a mathematical process to reduce the variation in a measurement by summing the data points from multiple measurements and dividing by the number of points summed.

Fall Time
Fall time is the time required for the amplitude of a pulse to decrease (fall) from a specified value (usually 90 percent of the peak value exclusive of overshoot or undershoot) to another specified value (usually 10 percent of the maximum value exclusive of overshoot or undershoot).

Noise Density
Noise Density is the amount of noise within a defined bandwidth, usually normalized to 1 Hz.

Resolution Bandwidth (RBW)
Resolution Bandwidth (RBW) is the minimum bandwidth over which you can separate two signals and still see them.


I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: