SORENSEN DCS150-20E REPAIR and CALIBRATION

 
Custom-Cal has a high success rate in the repair of the SORENSEN DCS150-20E. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another DC Power Supply?
Shop for Comparable Products on our
 used DC Power Supply page

 
   SORENSEN DCS150-20E   Description / Specification:    
SORENSEN DCS150-20E 150V 20A Single Output DC Power Supply

The Sorensen DCS150-20E DC System Power Supply is a 3000-watt supply designed to provide highly stable, continuously variable output voltage and current for a broad range of development, system, and burn-in applications. The DCS-E Series employs high frequency switching regulator technology to achieve high power density and small package size. Features. Simultaneous digital display of both DC output voltage and current. Ten-turn potentiometer voltage and current controls permit high resolution setting of the output voltage and current from zero to the model-rated output. Front panel push button control of Output Standby Mode, OVP reset, Remote/Local Programming Mode selection, and preview of voltage, current, or OVP setpoints. External indicator signals for Remote Monitoring of OVP Status, Local/Remote Programming Status, Thermal Shutdown, and Output Voltage and Current. Current or Voltage Mode operation with Automatic Mode Crossover to respond to varying load requirements. Flexible output configuration where multiple units can be connected in series or in parallel to provide increased voltage or increased current. Remote Sensing to compensate for losses in power leads up to 1V per lead. Adjustable Over Voltage Protection (OVP). External Shutdown using AC, DC, or TTL compatible signals (positive or negative logic). Remote Voltage, Current Limit, and OVP Programming with selectable programming ranges. Specifications. Output Voltage: 0 to 150 V. Output Current: 0 to 20 A. Output Power: 3000 W. Line Regulation Voltage: 150 mV. Line Regulation Current: 20 mA. Load Regulation Voltage: 150 mV. Load Regulation Current: 20 mA. Meter Accuracy Voltage: 1.6 V. Meter Accuracy Current: 0.30 A. OVP Adjustment Range: 7.5 to 165 V. Output Noise and Ripple (V) (20 Hz - 20 MHz): Rms 30 mV, p-p 200 mV. Analog Programming Linearity Voltage: 800 mV. Analog Programming Linearity Current: 370 mA. Stability Voltage: 75 mV. Stability Current: 10 mA. Temperature Coefficient Voltage: 30 mV/°C. Temperature Coefficient Current: 6.0 mA/°C.



 

Standard Calibration $185.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the SORENSEN DCS150-20E. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Crest Factor
Crest factor or peak-to-average ratio (PAR) is a measurement of a waveform, calculated from the peak amplitude of the waveform divided by the RMS value of the waveform

Linearity
Linearity is the relative difference between the displayed power ratio, Dx/D0, and the actual (true) power ratio Px/P0 caused by changing the displayed power level from the reference level, D0, to an arbitrary displayed level, Dx.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.

Sensitivity
Sensitivity is the minimum magnitude of input signal required to produce a specified output signal having a specified signal-to-noise ratio, or other specified criteria.


I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: