Keysight (Agilent) U1213A CALIBRATION and Keysight (Agilent) U1213A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) U1213A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   Keysight (Agilent) U1213A   Description / Specification:   Spec Sheet 
Keysight (Agilent) U1213A 1000A Handheld Clamp Multimeter

The Agilent U1213A handheld clamp meter comes with clamp opening of 52 mm/2 inches and high current measurement capability of up to 1000 A (AC, DC, AC+ DC). With the large jaw size, these handhelds simplify current measurements for thick cables. It provide basic functions of a multimeter with wide measurement ranges to cater for a broad range of applications (ACA, DCV, ACV, OHM, audible continuity, diode and frequency tests). These meters also provide auto-ranging capability, built-in peak hold for in-rush current measurement, temperature and capacitance measurement capability, large backlight display and one-hand operation. Specifications. DC voltage ranges: 4, 40, 400, 1000 V. AC voltage ranges: 4, 40, 400, 1000 V. AC+DC voltage ranges: 4, 40, 400, 1000 V. Voltage (1 ms peak hold) ranges: 4, 40, 400, 1000 V. Diode: check/audible continuity test. Resistance ranges: 400, 4k, 40k, 400k, 4M, 40M ohm. Capacitance ranges: 4, 40, 400, 4000 µF. DC current ranges: 40, 400, 1000 A. AC current ranges: 40, 400, 1000 A. AC+DC current ranges: 40, 400, 1000 A. Current (1 ms peak hold) ranges: 40, 400, 1000 A. Temperature test Thermal type K ranges: –200 ~ –40 °C, –40 ~ 1372 °C, –328 ~ –40 °F, –40 ~ 2502 °F. Frequency (AC coupling) ranges: 99.99, 999.9 Hz, 9.999, 99.99, 999.9 kHz. Display: 4 digits with maximum reading 4,100 counts. The 12 Segments analog bar graph and full annunciator. Automatic polarity indication. Connectivity: Wireless Bluetooth compatible.



 

Standard Calibration $160.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) U1213A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Clipping
Clipping is the limiting of a signal so that it never exceeds some threshold.

Line Regulation
Line regulation is the capability to maintain a constant output voltage level on the output channel of a power supply despite changes to the input voltage level.

Peak Envelope Power
Peak envelope power is the maximum value of the envelope power. Envelope power is measured by making the averaging time much less than 1/fm where fm is the maximum frequency component of the modulation waveform. The averaging time is therefore limited on both ends: (1) it must be small compared to the period of the highest modulation frequency, and (2) it must be large enough to be many RF cycles long.

RMS
RMS or root mean square is a statistical measure of the magnitude of a varying quantity


Please contact us for your Keysight (Agilent) U1213A CALIBRATION and/or Keysight (Agilent) U1213A 1000A Handheld Clamp Multimeter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: