THORLABS OSA205 CALIBRATION and THORLABS OSA205 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the THORLABS OSA205 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Optical Spectrum Analyzer, OSA?
Shop for Comparable Products on our
 used Optical Spectrum Analyzer, OSA page or new Optical Spectrum Analyzer, OSA page

As an alternative New Ridge Technologies offers the NRT-8000, the world’s Smallest Optical Spectrum Analyzer with built in “live wavelength calibration” for C-Band applications.  More
   THORLABS OSA205   Description / Specification:    
THORLABS OSA205 1000 to 5600 nm USB Optical Spectrum Analyzer

The Thorlabs OSA205 Optical Spectrum Analyzer is a general-purpose instrument that measures optical power as a function of wavelength. It has a user friendly Graphical User Interface and can be controlled from a standard PC via High Speed USB 2.0 port. It is a Fourier Transform Optical Spectrum Analyzer (FT-OSA), which utilizes a scanning Michelson Interferometer in a push/pull configuration. This approach allows for the design of a full-featured OSA with the additional benefit of a high precision Wavelength Meter.
Specifications.

Wavelength Range: 1000 - 5600 nm.
Spectral Resolution: 7.5 GHz.
Spectral Accuracy: ±2 ppm.
Spectral Precision: 1 ppm.
Wavelength Meter Resolution: 0.1 ppm, Wavelength Meter Mode Linewidth < 10 GHz.
Wavelength Meter Display Resolution: 9 Decimals, Wavelength Meter Mode Linewidth < 10 GHz.
Wavelength Meter Precision: 0.2 pm.
Input Power (Max), CW Source: 10 mW (10 dBm).
Power Level Accuracy: ±1 dB.
Optical Rejection Ratio: 30 dB.
Level Sensitivity: -40 dBm/nm.



 

Standard Calibration $1,200.00 *
*This is a Web introductory price for one calibration of the THORLABS OSA205. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Optical Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Bit Error Ratio (BER)
Bit Error Ratio (BER) is the ratio of errors caused by the number of bits in a data stream that have been altered due to noise, interference, distoriton or bit synchronization errors.

Flatness
Variation of insertion loss on the passband of an optical device.

Polarization Dependent Loss (PDL)
Polarization Dependent Loss is the difference between the maximum and minimum values of loss due to the variation of the polarization states of light propagating through a device. PDL is expressed in decibels. Calculated by; PDL = 10 log10 (Ep/Es), where EP and ES are the measured diffraction efficiencies for P- and S-plane polarized incident light, respectively.

Return Loss (RL)
Return Loss (RL) is the ratio of the incident power to the reflected power expressed in dB. RL = 10log (Pin/Pback)

Wavelength Resolution
Wavelength Resolution is the smallest possible displayed wavelength increment/decrement.


Please contact us for your THORLABS OSA205 CALIBRATION and/or THORLABS OSA205 1000 to 5600 nm USB Optical Spectrum Analyzer REPAIR

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: