Custom-Cal has a high success rate in the repair of the Keysight (Agilent) 34970A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 34970A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Data Acquisition?
Shop for Comparable Products on our
 used Data Acquisition page

 
   Keysight (Agilent) 34970A   Description / Specification:    
Keysight (Agilent) 34970A 3-Slot Data Acquisition/Switch Unit with 6 1/2 Digit DMM

The Agilent 34970A consists of a three-slot mainframe with a built-in 6 1/2 digit digital multimeter. Each channel can be configured independently to measure one of 11 different functions without the added cost or hassles of signal-conditioning accessories. Choose from eight optional plug-in modules to create a compact data logger, full-featured data acquisition system or low-cost switching unit. On-module screw-terminal connections eliminate the need for terminal blocks and a unique relay maintenance feature counts every closure on every switch for easy, predictable relay maintenance. Description. 3-slot mainframe with built-in GPIB and RS232 interfaces. 6 1/2-digit (22-bit) internal DMM, scanning up to 250 channels per second. 8 switch and control plug-in modules to choose from. Built-in signal conditioning measures thermocouples, RTDs and thermistors, ac/dc volts and current; resistance; frequency and period. 50k readings of non-volatile memory holds data when power is removed. Hi/LO alarm limits on each channel, plus 4 TTL alarm outputs. Option 001: Delete Internal DMM. Plug-in Modules: 34901A 20 Channel Multiplexer (2/4-wire) Module. 34902A 16 Channel Multiplexer (2/4-wire) Module. 34903A 20 Channel Actuator/GP Switch Module. 34904A 4 x 8 Two-Wire Matrix Module. 34905A 2 GHz Dual 1:4 RF Mux, 50 Ohm Module. 34906A 2 GHz Dual 1:4 RF Mux, 75 Ohm Module. 34907A Multifunction Module. 34908A 40 Channel Single-Ended Multiplexer Module.



 

Standard Calibration $245.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 34970A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Average Power
Average power means that the energy transfer rate is to be averaged over many periods of the lowest frequency involved. For a CW signal, the lowest frequency and highest frequency are the same, so average power and power are the same. For an amplitude modulated wave, the power must be averaged over many periods of the modulation component of the signal as well.

Dynamic range
Dynamic range the ratio of a specified maximum level of a parameter, such as power, current, voltage or frequency, to the minimum detectable value of that parameter.

Modulation
Modulation is the process by which the characteristic of one wave (the carrier) is modified by another.

Repeatability
Repeatability is the variation in a number of repeated measured quantities when measurement conditions are changed and restored. The value corresponds to half the spread between the minimum and maximum value measured.


Please contact us for your Keysight (Agilent) 34970A REPAIR and/or Keysight (Agilent) 34970A 3-Slot Data Acquisition/Switch Unit with 6 1/2 Digit DMM CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: