A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the SLAUGHTER 2945 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   SLAUGHTER 2945   Description / Specification:    
SLAUGHTER 2945 5KVAC, 6KVDC Withstanding Voltage/Insulation Resistance Test

The Slaughter 2945 Hipot tester was designed to provide safe, reliable, and cost-effective electrical safety testing. It complies with agency requirements from such agencies as UL, TÜV, CSA, VDE, and IEC.
Specifications.

Dielectric Withstand Test Mode.
Input Voltage: 115/230V selectable, ± 15% variation 47 - 63Hz.
Output Rating: AC 0 - 5000V, 2V/step, 12mA, DC 0 - 6000V, 2V/step, 5mA.
Output Regulation: ± (1% of output + 5V).
Voltage Setting: 0V - Max output rating, 10 volt step.
Voltage Setting Accuracy: ± (2% of Setting + 5V) (relative to displayed output).
Output Frequency: DC and 50/60Hz selectable.
Ripple: < 5% at 6KVDC/5mA.
Wave Form Sinewave Distortion : < 2% THD.
Dwell Time Setting: 0 & 0.2 - 999.9 seconds, 0.1 second/step “0” for continuous running.
Ramp Time Setting: 0 & 0.2 - 999.9 seconds, 0.1 second/step 0 ramp setting = 0.1 seconds fixed ramp.
Failure Settings AC Mode;
  High limit: 0.10 - 12.00mA, 0.01mA/step.
  Low limit: 0.00, 0.10 - 12.00mA, 0.01mA/step (0 = OFF).
  Accuracy: ± (2% of setting + 0.02mA).
Failure Settings DC Mode;
  High limit: 0.02 - 5.00mA, 0.01mA/step.
  Low limit: 0.00, 0.02 - 5.00mA, 0.01mA/step (0 = OFF).
  Accuracy: ± (2% of setting + 0.02mA).
Discharge Time: ≤ 300ms.
Ground Continuity Check;
  Current: DC 0.1A ± 0.01A, fixed.
  Maximum ground resistance: 1Ω ± 0.1Ω, fixed.

Insulation Resistance Test Mode.
Output Voltage;
  Range: 100 - 1000 Volts DC.
  Resolution: 10 volt/step.
  Accuracy: ± (2% of reading + 5 volts).
Voltage Display;
  Range: 0 - 1000V.
  Resolution: 10 volt/step.
  Accuracy: ± (2% of reading + 2 counts).
Resistance Display;
  Range: 1 - 1000MΩ (4 Digit, Auto Ranging).
  Resolution 500VDC: 0.0 MΩ (1.00 - 40.00 MΩ), 0.1 MΩ (35.0 - 999.9 MΩ).
  Resolution 1000VDC: 0.0 MΩ (1.00 - 80.00 MΩ), 0.1 MΩ (75.0 - 999.9 MΩ).
  Accuracy: ± (3% of reading + 2 counts) at test voltage > 500V, ± (7% of reading +2 counts) at test voltage = 500V.
High Resistance Limit Range: 0 - 1000MΩ (0 = Off ).
Low Resistance Limit Range: 1 - 1000MΩ.



 

Standard Calibration $285.00 *
*This is a Web introductory price for one calibration of the SLAUGHTER 2945. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Averaging
Averaging is a mathematical process to reduce the variation in a measurement by summing the data points from multiple measurements and dividing by the number of points summed.

Fall Time
Fall time is the time required for the amplitude of a pulse to decrease (fall) from a specified value (usually 90 percent of the peak value exclusive of overshoot or undershoot) to another specified value (usually 10 percent of the maximum value exclusive of overshoot or undershoot).

Noise Density
Noise Density is the amount of noise within a defined bandwidth, usually normalized to 1 Hz.

Resolution Bandwidth (RBW)
Resolution Bandwidth (RBW) is the minimum bandwidth over which you can separate two signals and still see them.


Please contact us for your SLAUGHTER 2945 CALIBRATION and/or SLAUGHTER 2945 5KVAC, 6KVDC Withstanding Voltage/Insulation Resistance Test REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: