INSTEK GPT-9903A CALIBRATION and INSTEK GPT-9903A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the INSTEK GPT-9903A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   INSTEK GPT-9903A   Description / Specification:    
INSTEK GPT-9903A 5KV AC, 6KV DC Withstanding Voltage / IR Tester

The GW Instek GPT- 9903A is capable of performing AC withstanding, DC withstanding and insulation resistance tests needed for the compliance of the safety standards such as IEC, EN, UL, CSA, GB, JIS and other safety regulations. The output voltage is automatically cut off (within 150μs) upon the detection of an abnormal output voltage or a trip of current limits during test to protect the operator from hazardous injury. It automatically discharges the DUT after each test to eliminate excessive voltage that remains on the DUT.
Specifications.

AC Withstanding.
Output-Voltage Range: 0.050kV to 5.000kV ac.
Output-Voltage Resolution: 2V/step.
Output-Voltage Accuracy: ± (1% of setting +5V) [no load].
Maximum Rated Load: 500 VA (5kV/100mA).
Maximum Rated Current: 100mA (0.5kV < V ≤ 5kV), 10 mA (0.05kV ≤ V≤ 0.5kV).
Output-Voltage Waveform: Sine wave.
Output-Voltage Frequency: 50 Hz / 60 Hz selectable.
Voltmeter Accuracy: ± (1% of reading+ 5V).
Current Measurement Range: 0.001 mA to 100.0 mA.
Current Best Resolution: 0.001mA / 0.01mA / 0.1mA.
AC Current Measurement Accuracy: ±(1.5% of reading +30 counts) when HISET < 1.11mA, ±(1.5% of reading +3 counts) when HISET ≥ 1.11mA.
ARC Detect: Yes.
RAMP (Ramp-Up Time): 0.1 to 999.9s.
TIMER (Test Time): OFF, 0.5s to 999.9s.
Sweep Function: Yes.
GND: ON/OFF.

DC Withstanding.
Output-Voltage Range: 0.050kV to 6.000kV dc.
Output-Voltage Resolution: 2V/step.
Output-Voltage Accuracy: ± (1% of setting +5V) [no load].
Maximum Rated Load: 100W (5kV/20mA).
Maximum Rated Current: 20mA (0.5kV < V ≤ 6kV), 2mA (0. 05kV ≤ V≤ 0.5kV).
Voltmeter Accuracy: ± (1% of reading+ 5V).
Current Measurement Range: 0.001mA to 20.0mA.
Current Best Resolution: 0.001mA / 0.01mA / 0.1mA.
DC Current Measurement Accuracy: ±(1.5% of reading +30 counts) when HISET < 1.11mA, ±(1.5% of reading +3 counts) when HISET ≥ 1.11mA.
ARC Detect: Yes.
RAMP (Ramp-Up Time): 0.1 to 999.9s.
TIMER (Test Time): OFF, 0.5s to 999.9s.
Sweep Function: Yes.
GND: ON/OFF.

Insulation Resistance.
Output-Voltage: 50V to 1000V dc.
Output-Voltage Resolution: 50V/step.
Output-Voltage Accuracy: ± (1% of setting +5V) [no load].
Resistance Measurement Range: 0.001G Ω to 50.00G Ω.



 

Standard Calibration $240.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the INSTEK GPT-9903A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBm
dBm (sometimes dBmW) is an abbreviation for the power ratio in decibels (dB) of the measured power referenced to one milliwatt (mW). Zero dBm equals one milliwatt. A 3 dB increase represents roughly doubling the power, a 3 dB decrease, the power is reduced by about one half.

Millimeter-wave
Millimeter-wave is a term that generally refers to frequencies of 26.5 GHz and above. That is where signal wavelengths fall below approximately 10 mm, and thus the terminology changes from centimeters to millimeters.

Power Repeatability
Power Repeatability is the random uncertainty in reproducing the power level after changing and re-setting the power level. The power repeatability is ± half the span (in dB) between the highest and lowest actual power. Note: - The long-term power repeatability can be obtained by taken the power repeatability and power stability into account.

Stability
Stability is the extent to which a specified property, characteristic, or parameter of a substance, device, or apparatus, remains fixed with the passage of time or with varying environmental conditions.


Please contact us for your INSTEK GPT-9903A CALIBRATION and/or INSTEK GPT-9903A 5KV AC, 6KV DC Withstanding Voltage / IR Tester REPAIR

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: