TRANSMILLE EA002 CALIBRATION and TRANSMILLE EA002 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the TRANSMILLE EA002 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Calibration Standard? Shop for Comparable Products on our   new Calibration Standard page

 
For Sale New, List Price $1,372.00   TRANSMILLE EA002   Description / Specification:    
TRANSMILLE EA002 Clamp Coil Adapter

The Transmille EA002 Clamp Coil Adapter is designed for the calibration of both wound (AC only) & Magnetic field (hall effect) AC/DC clamp meters the current coil offers several unique features built in a robust construction. The coil is designed to immerse both jaws of the clamp meter in the magnetic field while allowing the ‘gap’ or opening where magnetic flux will escape to protrude through the coil and stay out of the strongest part of the field. This makes the reading less dependent on the position of the clamp within the coil and also the quality of the jaw closing, allowing greater confidence in the calibration.
Specifications.

Connection to Calibrator: Via supplied 4mm to 4mm connection leads (x2) to 3000 series current terminals.
Coil Configuration: 2 Turn (LHS), 10 Turn (RHS), 50 Turn (CENTRE).
Coil Type: High accuracy balanced configuration.
Min. internal jaw dimensions: 10mm (2 Turn & 10 Turn), 25mm (50 Turn).
Maximum Current: 30A.
Maximum RMS voltage: 4V.
Frequency Range: DC to 500Hz.

2 Turn Coil Accuracy (Input 0 to 30A : Freq. DC - 30Hz to 60Hz : Effective Output 0 to 60A).
Effective accuracy - Coil only (wound clamps, 90 Day Rel.) 0.35% + 0.008A.
Effective accuracy - Coil only (hall effect clamps, 90 Day Rel.) 0.48% + 0.07A.

10 Turn Coil Accuracy (Input 0 to 30A : Freq. DC - 30Hz to 60Hz : Effective Output 0 to 300A).
Effective accuracy - Coil only (wound clamps, 90 Day Rel.) 0.41% + 0.01A.
Effective accuracy - Coil only (hall effect clamps, 90 Day Rel.) 0.59% + 0.11A.

50 Turn Coil Accuracy (Input 0 to 30A : Freq. DC - 30Hz to 60Hz : Effective Output 0 to 1500A).
Effective accuracy - Coil only (wound clamps, 90 Day Rel.) 0.24% + 0.04A.
Effective accuracy - Coil only (hall effect clamps, 90 Day Rel.) 0.45% + 0.42A.



 



Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Crest Factor
Crest factor or peak-to-average ratio (PAR) is a measurement of a waveform, calculated from the peak amplitude of the waveform divided by the RMS value of the waveform

Linearity
Linearity is the relative difference between the displayed power ratio, Dx/D0, and the actual (true) power ratio Px/P0 caused by changing the displayed power level from the reference level, D0, to an arbitrary displayed level, Dx.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.

Sensitivity
Sensitivity is the minimum magnitude of input signal required to produce a specified output signal having a specified signal-to-noise ratio, or other specified criteria.


Please contact us for your TRANSMILLE EA002 CALIBRATION and/or TRANSMILLE EA002 Clamp Coil Adapter REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: