A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) U1194A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   Keysight (Agilent) U1194A   Description / Specification:    
Keysight (Agilent) U1194A 600A Handheld Clamp Multimeter

The Keysight U1194A clamp meter has a unique wire separator allows you to effortlessly isolate and perform measure­ments on individual wires in a bundle. For improved visibility when making measurements, these clamp meters also come with an easily activated built-in LED flashlight that illuminates the test area.
Specifications.

Display: 6,000 counts.
RMS method: True RMS.

DC Voltage;
  
Range: 60 V, 0.01 V (Resolution), 0.5% + 3 (Accuracy).
  Range: 600 V, 0.1 V (Resolution), 0.5% + 3 (Accuracy).
Resistance;
  Range: 600 Ω, 0.1 Ω (Resolution), 0.8% + 5 (Accuracy).
  Range: 6 kΩ, 0.001 kΩ (Resolution), 0.8% + 3 (Accuracy).
  Range: 60 kΩ, 0.01 kΩ (Resolution), 0.8% + 3 (Accuracy).
Diode;
  Range: 1.5 V, 0.001 V (Resolution), 1.0% + 3 (Accuracy).
DC Current;
  Range: 60 μA, 0.01 μA (Resolution), 1.0% + 5 (Accuracy).
  Range: 600 μA, 0.1 μA (Resolution), 1.0% + 5 (Accuracy).
  Range: 60 A, 0.01 A (Resolution), 2.0% + 5 (Accuracy).
  Range: 600 A, 0.1 A (Resolution), 2.0% + 5 (Accuracy).
AC Voltage;
  Range: 60 V, 0.01 V (Resolution), 1.2% + 5 (Accuracy).
  Range: 600 V, 0.1 V (Resolution), 1.2% + 5 (Accuracy).
AC Current;
  Range: 60 μA, 0.01 μA (Resolution), 1.0% + 5 at 45 to 65 Hz (Accuracy).
  Range: 600 μA, 0.1 μA (Resolution), 1.0% + 5 at 45 to 65 Hz (Accuracy).
  Range: 60 A, 0.01 A (Resolution), 2.0% + 5 at 45 to 65 Hz (Accuracy).
  Range: 600 A, 0.1 A (Resolution), 2.0% + 5 at 45 to 65 Hz (Accuracy).
Capacitance;
  Range: 600 μF, 0.1 μF (Resolution), 2.0% + 4 (Accuracy).
  Range: 6 mF, 0.001 mF (Resolution), 2.0% + 4 (Accuracy).
Frequency;
  Range: 99.99 Hz, 0.01 Hz (Resolution), 0.5% + 3 (Accuracy).
  Range: 999.9 Hz, 0.1 Hz (Resolution), 0.5% + 3 (Accuracy).
  Range: 9.999 kHz, 0.001 kHz (Resolution), 0.5% + 3 (Accuracy).
  Range: 99.99 kHz, 0.01 kHz (Resolution), 0.5% + 3 (Accuracy).
Temperature, Thermal type K;
  Range: -40 to 400 °C, 0.1 °C (Resolution), 1.0% + 2.0 °C (Accuracy).
  Range: 400 to 1,200 °C, 1.0 °C (Resolution), 1.0% + 2.0 °C (Accuracy).
  Range: -40 to 752 °F, 0.1 °F (Resolution), 1.0% + 3.6 °F (Accuracy).
  Range: 752 to 2,192 °F, 1.0 °F (Resolution), 1.0% + 3.6 °F (Accuracy).



 



Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Clipping
Clipping is the limiting of a signal so that it never exceeds some threshold.

Line Regulation
Line regulation is the capability to maintain a constant output voltage level on the output channel of a power supply despite changes to the input voltage level.

Peak Envelope Power
Peak envelope power is the maximum value of the envelope power. Envelope power is measured by making the averaging time much less than 1/fm where fm is the maximum frequency component of the modulation waveform. The averaging time is therefore limited on both ends: (1) it must be small compared to the period of the highest modulation frequency, and (2) it must be large enough to be many RF cycles long.

RMS
RMS or root mean square is a statistical measure of the magnitude of a varying quantity


Please contact us for your Keysight (Agilent) U1194A CALIBRATION and/or Keysight (Agilent) U1194A 600A Handheld Clamp Multimeter REPAIR

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: