FOTRIC 226B CALIBRATION and FOTRIC 226B REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the FOTRIC 226B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Special Test Set? Shop for Comparable Products on our   new Special Test Set page

 
For Sale New, List Price $4,499.00   FOTRIC 226B   Description / Specification:    
FOTRIC 226B Infrared Camera System

The FOTRIC 226B Auto Body Temperature Screening Infrared Imager is not marketed or intended to be used as a medical device. The Fotric 226B can only be used to measure temperature. This device does not determine the core body temperature of subjects. Actual core body temperature can only be determined using an approved clinical measurement device. The 226B temperature (IR) measurement should not be solely or primarily relied upon to diagnose or exclude a diagnosis of COVID-19, or any other disease. The Fotric 226E uses face detection with customizable settings built into the camera to define the area for temperature measurement. It is not used for facial recognition, nor is it classified as a medical device. The working principle of the HawkAI mode is that the FOTRIC 226B first collects the human body surface (face) temperature and then automatically calculates the compensation temperature through the AI algorithm. This converts the human body surface temperature into the real body temperature. HawkAI mode can adjust the compensation temperature value in real time according to the flow of people continuously passing the temperature measurement point to adapt to the change of ambient temperature.
Specifications.

IR Resolution: 304 x 288 pixels.
Thermal Sensitivity (NETD): <0.05°C @30°C.
Field of View (FOV}: 28°H x 21°V.
Detector Type: Polysillicon-FPA, uncooled microbolometer, 17um, Spectral Range 8-14um.
Frame Rate: 50Hz.
Temperature Range: 20°C -60°C (68°F-140°F).
Temperature Stability: ±0.5°C.
Al Face Detection: Dual Light Detection (visible light and infrared thermal).
Al Body Temperature Algorithm: Calibrate alarm thresholds in real time based on ambient temperature.
Statistic Function: Automatic statistics of screening number.
Shooting Mode: Automatic abnormal temperature snap shot or manual shooting.
Alarm Function: Both color alarm and sound alarm.
Color Pallet: Black-White/Iron/Rainbow.
Image Format: Standard J PEG with temperature data.
Interlace Connection: USB.
Software: WLJR Body Temperature Screening Software.
Operating Temperature: 0°C -40°C (32°F-104°F).
Storage Temperature: -20°C -50°C (-4°F-122°F).
Enclosure Rating: IP40.
Charging System: DC 12V Charger.
Weight: ±560g.
Dimensions (LxHxW): 97mm x 145mm x93.5mm.
Tripod Mounting: UNC ¼-20.



 

Standard Calibration $390.00 *
*This is a Web introductory price for one calibration of the FOTRIC 226B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBm
dBm (sometimes dBmW) is an abbreviation for the power ratio in decibels (dB) of the measured power referenced to one milliwatt (mW). Zero dBm equals one milliwatt. A 3 dB increase represents roughly doubling the power, a 3 dB decrease, the power is reduced by about one half.

Millimeter-wave
Millimeter-wave is a term that generally refers to frequencies of 26.5 GHz and above. That is where signal wavelengths fall below approximately 10 mm, and thus the terminology changes from centimeters to millimeters.

Power Repeatability
Power Repeatability is the random uncertainty in reproducing the power level after changing and re-setting the power level. The power repeatability is ± half the span (in dB) between the highest and lowest actual power. Note: - The long-term power repeatability can be obtained by taken the power repeatability and power stability into account.

Stability
Stability is the extent to which a specified property, characteristic, or parameter of a substance, device, or apparatus, remains fixed with the passage of time or with varying environmental conditions.


Please contact us for your FOTRIC 226B CALIBRATION and/or FOTRIC 226B Infrared Camera System REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: