THORLABS OSA207 CALIBRATION and THORLABS OSA207 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the THORLABS OSA207 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Optical Spectrum Analyzer, OSA?
Shop for Comparable Products on our
 used Optical Spectrum Analyzer, OSA page or new Optical Spectrum Analyzer, OSA page

As an alternative New Ridge Technologies offers the NRT-8000, the world’s Smallest Optical Spectrum Analyzer with built in “live wavelength calibration” for C-Band applications.  More
   THORLABS OSA207   Description / Specification:    
THORLABS OSA207 1000 to 12000 nm USB Optical Spectrum Analyzer

The Thorlabs OSA207 Optical Spectrum Analyzer is a general-purpose instrument that measures optical power as a function of wavelength. It has a user friendly Graphical User Interface and can be controlled from a standard PC via High Speed USB 2.0 port. It is a Fourier Transform Optical Spectrum Analyzer (FT-OSA), which utilizes a scanning Michelson Interferometer in a push/pull configuration. This approach allows for the design of a full-featured OSA with the additional benefit of a high precision Wavelength Meter.
Specifications.

Wavelength Range: 1000 - 12000 nm.
Spectral Resolution: 7.5 GHz.
Spectral Accuracy: ±2 ppm.
Spectral Precision: 1 ppm.
Wavelength Meter Resolution: 0.1 ppm, Wavelength Meter Mode Linewidth < 10 GHz.
Wavelength Meter Display Resolution: 9 Decimals, Wavelength Meter Mode Linewidth < 10 GHz.
Wavelength Meter Accuracy: ±1 ppm.
Wavelength Meter Precision: 0.2 ppm.
Input Power (Max), CW Source: 10 mW (10 dBm).
Input Damage Threshold: 20 mW (13 dBm).
Power Level Accuracy: ±1 dB.
Optical Rejection Ratio: 30 dB.
Level Sensitivity: -30 dBm/nm (1.0 - 2.0 μm), -40 dBm/nm (2.0 - 12.0 μm).



 

Standard Calibration $1,425.00 *
*This is a Web introductory price for one calibration of the THORLABS OSA207. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Optical Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Amplified Spontaneous Emission Source (ASE)
ASE, a process where spontaneously emitted radiation (luminescence) is amplified. In lasers and particularly in high-gain erbium-doped amplifiers, amplified spontaneous emission is usually an unwanted effect. It tends to limit the gain achievable in a single stage of a fiber optic amplifier to the order of 40–50 dB.

Dynamic Range
In a transmission system, the ratio of the overload level to the noise level of the system, usually expressed in dB. Ratio of the highest to lowest detectable signal of a system, expressed in dB.

Optical Power
Optical Power is usually measured in "dBm", or decibels referenced to one miliwatt of power. while loss is a relative reading, optical power is an absolute measurement, referenced to standards. You measure absolute power to test transmitters or receivers and relative power to test loss.

Relative Wavelength Accuracy
When randomly changing the wavelength and measuring the differences between the actual and displayed wavelengths, the relative wavelength accuracy is ± half the span between the maximum and the minimum value of all differences.

Wavelength
Wavelength is a term for the color of light, usually expressed in nanometers (nm) or microns (m). In Fiber Optics the wavelenghts mostly used are in the infrared region where the light is invisible to the human eye.


Please contact us for your THORLABS OSA207 CALIBRATION and/or THORLABS OSA207 1000 to 12000 nm USB Optical Spectrum Analyzer REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  