KEYSIGHT U2000A CALIBRATION and KEYSIGHT U2000A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the KEYSIGHT U2000A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another RF Power Sensor?
Shop for Comparable Products on our
 used RF Power Sensor page

 
   KEYSIGHT U2000A   Description / Specification:    
KEYSIGHT U2000A 10 MHz – 18 GHz USB Power Sensor

The Keysight U2000A is a standalone RF Power Sensor that operates like a power meter. It's fast measurement speed helps reduce test time. This, coupled with the capability to enable monitoring of more than 20 channels simultaneously, is an advantage in the production line where efficiency is of utmost priority. The U2000A has both internal and external zeroing capabilities. With internal zeroing, high isolation switches in the sensor are opened to isolate the sensor from the device-under- test (DUT) it is connected to. The U2000A USB power sensor is a true-average, wide-dynamic-range RF/microwave power sensors, based on a dual-sensor diode pair/ attenuator/diode pair topology.
Specifications.

Frequency range: 10 MHz to 18 GHz.
Power range: -60 to +20 dBm.
Maximum power: +25 dBm avg 20 VDC, +33 dBm pk < 10 µs.
Maximum SWR:
  1.15 (10 to 30 MHz),
  1.13 (30 MHz to 2 GHz),
  1.19 (2 to 14 GHz),
  1.22 (14 to 16 GHz),
  1.26 (16 to 18 GHz).
Measurement speed Normal: 20 readings/s.
Measurement speed Fast: 110 readings/s.
Average only mode (default mode): optimized for wide dynamic range. In this measurement mode, a trigger can be controlled externally via TTL input.
Normal mode: used for making average power measurement in a defined time interval (time-gated measurement) with reduced dynamic range. A trigger can be derived from an RF signal (internal trigger) or controlled externally via TTL input (external trigger).
Accuracy (25 °C ± 10 °C): ±3.0% (60 to +20 dBm).
Current requirement: 200 mA max (approximately).
Connector type: N-type male, 50 ohm.



 

Standard Calibration $285.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the KEYSIGHT U2000A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Available Gain
Available Gain is the ratio, at a specific frequency, of power available from the output to the power in from the source.

Frequency Span
Frequency Span specifies the range between the start and stop frequencies, also referred to as bandwidth

Peak Envelope Power
Peak envelope power is the maximum value of the envelope power. Envelope power is measured by making the averaging time much less than 1/fm where fm is the maximum frequency component of the modulation waveform. The averaging time is therefore limited on both ends: (1) it must be small compared to the period of the highest modulation frequency, and (2) it must be large enough to be many RF cycles long.


Please contact us for your KEYSIGHT U2000A CALIBRATION and/or KEYSIGHT U2000A 10 MHz – 18 GHz USB Power Sensor REPAIR

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: