KEYSIGHT U1194A CALIBRATION and KEYSIGHT U1194A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the KEYSIGHT U1194A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

 

 
   KEYSIGHT U1194A   Description / Specification:    
KEYSIGHT U1194A 600A Handheld Clamp Multimeter

The Keysight U1194A clamp meter has a unique wire separator allows you to effortlessly isolate and perform measure­ments on individual wires in a bundle. For improved visibility when making measurements, these clamp meters also come with an easily activated built-in LED flashlight that illuminates the test area.
Specifications.

Display: 6,000 counts.
RMS method: True RMS.

DC Voltage;
 
Range: 60 V, 0.01 V (Resolution), 0.5% + 3 (Accuracy).
 Range: 600 V, 0.1 V (Resolution), 0.5% + 3 (Accuracy).
Resistance;
 Range: 600 Ω, 0.1 Ω (Resolution), 0.8% + 5 (Accuracy).
 Range: 6 kΩ, 0.001 kΩ (Resolution), 0.8% + 3 (Accuracy).
 Range: 60 kΩ, 0.01 kΩ (Resolution), 0.8% + 3 (Accuracy).
Diode;
 Range: 1.5 V, 0.001 V (Resolution), 1.0% + 3 (Accuracy).
DC Current;
 Range: 60 μA, 0.01 μA (Resolution), 1.0% + 5 (Accuracy).
 Range: 600 μA, 0.1 μA (Resolution), 1.0% + 5 (Accuracy).
 Range: 60 A, 0.01 A (Resolution), 2.0% + 5 (Accuracy).
 Range: 600 A, 0.1 A (Resolution), 2.0% + 5 (Accuracy).
AC Voltage;
 Range: 60 V, 0.01 V (Resolution), 1.2% + 5 (Accuracy).
 Range: 600 V, 0.1 V (Resolution), 1.2% + 5 (Accuracy).
AC Current;
 Range: 60 μA, 0.01 μA (Resolution), 1.0% + 5 at 45 to 65 Hz (Accuracy).
 Range: 600 μA, 0.1 μA (Resolution), 1.0% + 5 at 45 to 65 Hz (Accuracy).
 Range: 60 A, 0.01 A (Resolution), 2.0% + 5 at 45 to 65 Hz (Accuracy).
 Range: 600 A, 0.1 A (Resolution), 2.0% + 5 at 45 to 65 Hz (Accuracy).
Capacitance;
 Range: 600 μF, 0.1 μF (Resolution), 2.0% + 4 (Accuracy).
 Range: 6 mF, 0.001 mF (Resolution), 2.0% + 4 (Accuracy).
Frequency;
 Range: 99.99 Hz, 0.01 Hz (Resolution), 0.5% + 3 (Accuracy).
 Range: 999.9 Hz, 0.1 Hz (Resolution), 0.5% + 3 (Accuracy).
 Range: 9.999 kHz, 0.001 kHz (Resolution), 0.5% + 3 (Accuracy).
 Range: 99.99 kHz, 0.01 kHz (Resolution), 0.5% + 3 (Accuracy).
Temperature, Thermal type K;
 Range: -40 to 400 °C, 0.1 °C (Resolution), 1.0% + 2.0 °C (Accuracy).
 Range: 400 to 1,200 °C, 1.0 °C (Resolution), 1.0% + 2.0 °C (Accuracy).
 Range: -40 to 752 °F, 0.1 °F (Resolution), 1.0% + 3.6 °F (Accuracy).
 Range: 752 to 2,192 °F, 1.0 °F (Resolution), 1.0% + 3.6 °F (Accuracy).



 

Standard Calibration $150.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the KEYSIGHT U1194A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Channel Bandwidth
Channel Bandwidth is the bandwidth over which power is measured. This is usually the bandwidth in which almost all of the power of a signal is contained.

Jitter
Jitter in technical terms is the deviation in or displacement of some aspect of the pulses in a high-frequency digital signal. Jitter is the time variation of a periodic signal in electronics and telecommunications, often in relation to a reference clock source. Jitter may be observed in characteristics such as the frequency of successive pulses, the signal amplitude, or phase of periodic signals. Jitter is a significant, and usually undesired, factor in the design of almost all communications links (e.g., USB, PCI-e, SATA, OC-48). In clock recovery applications it is called timing jitter.

Overshoot
Overshoot is the distortion that follows a major transition; the difference between the peak power point and the pulse-top amplitude computed as a percentage of the pulse-top amplitude.

Rise Time
Rise time refers to the time required for a signal to change from a specified low value to a specified high value, usually 10 and 90 percent of pulse-top amplitude (vertical display is linear power).


Please contact us for your KEYSIGHT U1194A CALIBRATION and/or KEYSIGHT U1194A 600A Handheld Clamp Multimeter REPAIR

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: