KEYSIGHT U2722A CALIBRATION and KEYSIGHT U2722A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the KEYSIGHT U2722A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another General Meter?
Shop for Comparable Products on our
 used General Meter page

 
   KEYSIGHT U2722A   Description / Specification:    
KEYSIGHT U2722A 20V/120mA USB Modular Source Measure Unit

The Keysight U2722A USB Modular Source Measure Unit is a 3-channel 20V/120mA that can operate in a 4-quadrant operation. The channels could be connected in series or in parallel to achieve up to 60 V/360 mA. It uses the common non-proprietary standard high-speed USB 2.0 interface that provides ease of connectivity - allowing users to set up and configure their tests swiftly with its plug and play feature. The U2722A can function as a standalone module. It can also be used as a modular device, allowing expansion and compact solution when used with the other modules in the USB Modular Instruments and DAQ family.
Specifications.

Number of outputs: 3.
Voltage Output: -20 V to 20 V.
Current Output: -120 mA to 120 mA.
Voltage programming Ranges: ±2 V, ±20 V.
Voltage programming Max Resolution: 0.1 mV.
Current programming Ranges: ±1 µA, ±10 µA, ±100 µA, ±1 mA, ±10 mA, ±120 mA.
Current programming Max Resolution: 100 pA.
Voltage readback Ranges: ±2 V, ±20 V.
Voltage readback Max Resolution: 0.1 mV.
Current readback Ranges: ±1 µA, ±10 µA, ±100 µA, ±1 mA, ±10 mA, ±120 mA.
Current readback Max Resolution: 100 pA.
Remote sense operating range: Ensure that the maximum voltage between the OUTPUT+ and SENSE+, OUTPUT-, and SENSE- does not exceed 3 V.
Temperature coefficient: Maximum change in output/readback per °C after a 30-minute warm-up is 0.15. Guard output resistance: 0.2 kohm.
Noise 10 Hz to 20 MHz (peak-peak): 100 mV typical into a resistive load (floating mode).
Output voltage overshoot, ±(% of output + offset): During turn-on or turn-off, the output plus overshoot < 0.1% + 10 mV.
Programming language: SCPI (Standard Commands for Programmable Instruments).
Maximum sense lead resistance: 1 M-ohm for rated accuracy.



 

Standard Calibration $220.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the KEYSIGHT U2722A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Available Gain
Available Gain is the ratio, at a specific frequency, of power available from the output to the power in from the source.

Decibel (dB)
A unit of measurement of power which indicates relative power. A -10 dB means a reduction in power by 10 times, -20 dB means another 10 times or 100 times overall, -30 means another 10 times or 1000 times overall and so on.

Mismatch Uncertainty
Mismatch Uncertainty is caused by re-reflections between one device (the source) and the device that follows it (the load).

Pulse Power
Pulse Power, the energy transfer rate is averaged over the pulse width. Pulse width is considered to be the time between the 50 percent risetime/falltime amplitude points. Pulse power averages out any aberrations in the pulse envelope such as overshoot or ringing.


Please contact us for your KEYSIGHT U2722A CALIBRATION and/or KEYSIGHT U2722A 20V/120mA USB Modular Source Measure Unit REPAIR

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: