Keysight (Agilent) 70340A REPAIR and Keysight (Agilent) 70340A CALIBRATION

The Keysight (Agilent) 70340A is currently in stock and available for purchase on our  Sales Page
It is also available for immediate rental.
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) 70340A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 70340A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Signal Generator?
Shop for Comparable Products on our
 used Signal Generator page

 
   Keysight (Agilent) 70340A   Description / Specification:    
Keysight (Agilent) 70340A 20 GHz Synthesized Signal Generator, MMS

The HP 70340A Synthesized Signal Generator for 70000 Modular Measurement System (MMS), 4/8-width module delivers superior signal purity. Harmonics are suppressed above 55 dBc while other spurious signals are reduced below -60 dBc. Subharmonic signals are completely eliminated. Excellent output power accuracy (±2 dB) and flatness (±0.5 dB) are maintained across the entire> 100 dB dynamic range and the full frequency range of the HP 70340A, even at temperature extremes. The HP 70340A combines superior internal level accuracy and flatness with the flexibility of User Level Correction. This feature allows you to calibrate and program the signal generator output for automatic leveled power at distant test ports. Four level correction tables can be stored in memory for quick access as the system is reconfigured for different DUTs or test scenarios. Specifications. Frequency Range: 1 to 20 GHz. Frequency Resolution: 1 kHz, 1 Hz with Option 1E8. Leveled output power (with Option 1E1 installed): 10 MHz to 1 GHz +13 to -90 dBm, 1 GHz to 18 GHz +10 to -90 dBm, 18 GHz to 20 GHz +8 to -90 dBm. Resolution: 0.01 dB. Accuracy: ±2 dB (all frequencies, power levels and temperatures). Flatness: ±0.5 dB. Hannonlcs: < -55 dBc. Sub-harmonics: None. Non-harmonic spurious: -60 dBc. Options. 1E1, add output step attenuator. 1E2, add internal pulse modulation source. 1E8, add 1 Hz frequency resolution. 1E9, 3.5 mm RF output connector.



 

Standard Calibration $475.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 70340A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Carrier Wave (CW)
Carrier Wave or Continuous Wave is a sinusoidal signal without modulation.

Harmonic
A harmonic of a wave is a component frequency of the signal that is an integer multiple of the fundamental frequency, i.e. if the fundamental frequency is f, the harmonics have frequencies 2f, 3f, 4f, . . . etc.

Noise Floor
Noise floor is the measure of the signal created from the sum of all the noise sources and unwanted signals within a measurement system.

Ripple
Ripple is the small unwanted residual periodic variation of the direct current (dc) output


Please contact us for your Keysight (Agilent) 70340A REPAIR and/or Keysight (Agilent) 70340A 20 GHz Synthesized Signal Generator, MMS CALIBRATION

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: