Keysight (Agilent) 8153A REPAIR and Keysight (Agilent) 8153A CALIBRATION

The Keysight (Agilent) 8153A is currently in stock and available for purchase on our  Sales Page
It is also available for immediate rental.
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) 8153A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 8153A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Lightwave Measurement System?
Shop for Comparable Products on our
 used Lightwave Measurement System page or new Lightwave Measurement System page

 
   Keysight (Agilent) 8153A   Description / Specification:    
Keysight (Agilent) 8153A Lightwave Multimeter Mainframe

The HP 8153A Lightwave Multimeter Mainframe offers two slots for plug-in modules. Since modules can be combined in any configuration, the instrument can be used as a 1/2 channel power meter, a 1/2 channel light source, a loss test set, or even as a return loss test set. Four different power sensor modules, with different sensitivities from -70 dBm down to -110 dBm, cover the 450 nm to 1700 nm wavelength range. Each is individually calibrated over its entire wavelength range and is traceable to NIST and PTB for precise optical power measurements. The excellent linearity and high stability of the source modules provides the basis for precise determination of optical insertion loss for both single-mode and multimode components. The external power sensors (optical heads) cover the power range from +27 to -90 dBm. They are especially suitable for obtaining the highest requirements in absolute accuracy, e.g. for calibration services, and also for open beam measurements. The source modules offer very good short-term and long-term stability. The high output power can be internally attenuated by up to 6 dB. All sources are able to output CW or pulse-modulated light (internal modulation at 270 Hz, 1 kHz, or 2 kHz). Display Ranges. Power: +30 to -110 dBm or 1000.00 mW to 0.01 pW. Calibration Factor: ± 200.000 dB. Reference: ± 200.000 dBm/dB. Data Acquisition. Memory: 500 measurement results/channel (acquisition time >= 20 ms/data point). Selectable Data Averaging Time: 20 ms to 60 min. Selectable Total Data Acquisition Time: 20 ms to 99:59:59 h.



Looking for a replacement? Try the  UC INSTRUMENTS GM8001B

Functional Test $75.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 8153A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Optical Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Chirp
A change in the optical frequency caused by direct modulation of the laser. A chirp is a signal in which the frequency increases ('up-chirp') or decreases ('down-chirp') with time. In some sources, the term chirp is used interchangeably with sweep signal.

Isolation
The extent to which optical power from one signal path is prevented from reaching another signal path.

Polarization Extinction Ratio
Polarization Extinction Ratio is the ratio of optical power in the slow axis of the polarization maintaining fiber to optical power in the fast axis within a specified wavelength range.

Sidemode Suppression Ratio
Sidemode Suppression Ratio is the ratio of average signal power to the optical power of the highest sidemode within a distance from 0.1 to 6 GHz to the signal’s optical frequency, expressed in dB.

Wavelength Stability
Wavelength Stability is the change of wavelength during given time span, expressed as ± half the span between the maximum and the minimum of all actual wavelengths.


Please contact us for your Keysight (Agilent) 8153A REPAIR and/or Keysight (Agilent) 8153A Lightwave Multimeter Mainframe CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: