Keysight (Agilent) 83630B REPAIR and Keysight (Agilent) 83630B CALIBRATION

 
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) 83630B. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 83630B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Signal Generator?
Shop for Comparable Products on our
 used Signal Generator page

 
   Keysight (Agilent) 83630B   Description / Specification:    
Keysight (Agilent) 83630B 26.5 GHz Synthesized Sweeper

The HP 83630B Synthesized Swept-Signal Generator, combines excellent frequency resolution, level control, signal purity, and modulation capabilities you expect of a high-performance synthesized signal generator with the speed and convenience of a sweep oscillator. They are ideal for the demanding requirements of signal simulation, local oscillator, and stimulus/ response component or subsystem test applications. High-performance pulse modulators with >80 dB on/off ratio, and rise/ fall times < 10 ns (Option 006), make the HP 83630B suitable for the most demanding pulse modulation applications. In addition to its linear AM mode (100%/V), the HP 83630B offers a scan modulation mode (10 dB/V). Both modes have dc-coupled amplitude modulation capability with a 3 dB bandwidth of 100 kHz, and 99.7% (50 dB) of modulation depth. Pulse and amplitude modulation capabilities can be used independently and simultaneously. The HP 83630B also offers dc-coupled frequency modulation capabilities with rates up to 8 MHz. Specifications. Frequency Range: 10 MHz to 26.5 GHz. Resolution: 1 kHz (Option 008 1 Hz). Internal 10 MHz Time Base. Aging Rate: 5 x 10^-10/day, 1 x 10^-7/year. Output Power, Maximum Leveled: Output Frequencies <20 GHz +13 dBm, Output Frequencies >=20 GHz +10 dBm. Minimum Settable Output Power; Standard: -20 dBm, Option 001; -110 dBm. Resolution: 0.02 dB. Modulation; Pulse: On/Off Ratio 80 dB. Rise/Fall Times 25 ns. Minimum Width Internally Leveled 1 µs. AM and Scan; Bandwidth: (3 dB, 30% depth, modulation peaks 3 dB below maximum rated power): DC to 100 kHz. Modulation Depth: Normal Mode: –20 dBm to maximum available power. Options. Opt 001: Adds Step Attenuator. Opt 002: Adds Internal Modulation Generator. Opt 004: Rear-Panel RF Output. Opt 006: Fast-Pulse Modulation. Opt 008: 1 Hz Frequency Resolution. Opt 700: MATE System Compatibility.



 

Standard Calibration $730.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 83630B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Averaging
Averaging is a mathematical process to reduce the variation in a measurement by summing the data points from multiple measurements and dividing by the number of points summed.

Fall Time
Fall time is the time required for the amplitude of a pulse to decrease (fall) from a specified value (usually 90 percent of the peak value exclusive of overshoot or undershoot) to another specified value (usually 10 percent of the maximum value exclusive of overshoot or undershoot).

Noise Density
Noise Density is the amount of noise within a defined bandwidth, usually normalized to 1 Hz.

Resolution Bandwidth (RBW)
Resolution Bandwidth (RBW) is the minimum bandwidth over which you can separate two signals and still see them.


Please contact us for your Keysight (Agilent) 83630B REPAIR and/or Keysight (Agilent) 83630B 26.5 GHz Synthesized Sweeper CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: