Keysight (Agilent) 83712B REPAIR and Keysight (Agilent) 83712B CALIBRATION

 
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) 83712B. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 83712B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Signal Generator?
Shop for Comparable Products on our
 used Signal Generator page

 
   Keysight (Agilent) 83712B   Description / Specification:    
Keysight (Agilent) 83712B 20 GHz Synthesized CW Generator

The HP 83712B Synthesized CW Generator has fundamental oscillators and switched low-pass filters deliver < - 55 dBc harmonics, eliminate subharmonics, and suppress spurious to < - 60 dBc. These signal sources provide plenty of output power (typically > + 14 dBm), while spectral purity is maintained even at high power levels (typical output power at frequencies below 1 GHz is + 20 dBm). These signal sources deliver >100 dB dynamic range. Level resolution is 0.01 dB with typical accuracy of ± 1.0 dB at any frequency or power level. User Level Correction simplifies generating accurate, leveled power at distant test ports. The HP 83712B signal source is the recommended local oscillator for the HP 8970B noise figure meter. Low broadband noise minimizes errors in measurements of low gain devices. Use these signal sources with the HP 83550 series millimeter-wave modules to generate signals to 110 GHz. All front-panel functions are completely HP-IB-programmable and SCPI-compatible. Specifications. Frequency Range: 10 MHz to 20 GHz. Frequency Resolution: 1 kHz, 1 Hz with Opt 1E8. Output Power (with Option 1E1): 0.01 to 1 GHz (+13 dBm), 1 to 18 GHz (+10 dBm), 18 to 20 GHz (+8 dBm). Resolution: 0.01 dB. Accuracy (-4 dBm to maximum specified leveled output power): 10 MHz to 50 MHz, ±1.3 dB; 50 MHz to 20 GHz, ±1.0 dB. Harmonics: < -50 dBc (at levels < +10 dBm). Sub-Harmonics: None. Non-Harmonic Spurious (>3 kHz): -60 dBc. Options. Opt 1E1: Add 110 dB Output Step Attenuator. Opt 1E2: Add High-Performance Modulation Generator. Opt 1E5: Add High-Stability Timebase. Opt 1E8: Add 1 Hz Frequency Resolution. Opt 1E9: 3.5 mm RF Output Connector.



 

Standard Calibration $515.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 83712B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBc
dBc (decibels relative to the carrier) is the power ratio of a signal to a carrier signal, expressed in decibels. If the dBc figure is positive, then the relative signal strength is greater than the carrier signal strength. If the dBc figure is negative, then the relative signal strength is less than carrier signal strength.

Load Regulation
Load regulation is the capability to maintain a constant voltage (or current) level on the output channel of a power supply despite changes in the supply's load (such as a change in resistance value connected across the supply output).

Power Linearity
When changing the power level and measuring the differences (in dB) between actual and displayed power levels, the power linearity is ± half the span (in dB) between the maximum and the minimum value of all differences.

Settling Time
Settling time of an output device is the time elapsed from the application of an ideal instantaneous step input to the time at which the amplifier output has entered and remained within a specified error band, usually symmetrical about the final value.


Please contact us for your Keysight (Agilent) 83712B REPAIR and/or Keysight (Agilent) 83712B 20 GHz Synthesized CW Generator CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: