BK PRECISION 1652 CALIBRATION and BK PRECISION 1652 REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the BK PRECISION 1652 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another DC Power Supply?
Shop for Comparable Products on our
 used DC Power Supply page

 
   BK PRECISION 1652   Description / Specification:   Spec Sheet 
BK PRECISION 1652 Triple Output DC Power Supply

The B+K Precision 1652A is a Triple Output DC Power Supply with two variable 0 to 24 VDC outputs capable of supplying 0 to 500 mA, and one fixed 5 VDC output capable of supplying up to 4 A. Connect outputs in series for higher voltage or connect in parallel for higher current output (switch selectable). Voltage and current metering is provided by two, three-digit LED displays. This unit is fully protected against short circuit, overload, and reverse polarity. Specifications. Number of Outputs: Three (1 variable, 2 fixed). Output Voltage: 0 to 24 VDC (A & B), 5 VDC (C). Output Current: 0 to 500 mA (A & B), 4 A (C). Constant Voltage Operation Line Regulation: < 0.01% + 3 mV (main), < 5 mV for line fixed supply. Constant Voltage Operation Load Regulation: < 0.01% + 3 mV (main), < 10 mV fixed. CV Recovery time: 100 µS. CV Ripple & Noise (5 Hz to 1 MHz): <2 mVrms (<= 5 mVrms for fixed output). Constant Current (CC) Adjustable Current Range: 5% to 100%. CC Line Regulation: < 0.2% + 6 mA. CC Load Regulation: < 0.2% + 3 µA. CC Current Ripple: < 3 mA rms. Display: dual 3-digit LED. Voltmeter Accuracy: +(0.5% rdg + 2 digits). Ammeter Accuracy: +(0.5% rdg + 2 digits). Overload Protection: Current limiting, Reverse polarity, Overvoltage, Short circuit.



 

Standard Calibration $130.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the BK PRECISION 1652. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Crest Factor
Crest factor or peak-to-average ratio (PAR) is a measurement of a waveform, calculated from the peak amplitude of the waveform divided by the RMS value of the waveform

Linearity
Linearity is the relative difference between the displayed power ratio, Dx/D0, and the actual (true) power ratio Px/P0 caused by changing the displayed power level from the reference level, D0, to an arbitrary displayed level, Dx.

Phase Noise
Phase noise is the frequency domain representation of rapid, short-term, random fluctuations in the phase of a waveform, caused by time domain instabilities. Phase noise (L(f)) is typically expressed in units of dBc/Hz, representing the noise power relative to the carrier contained in a 1 Hz bandwidth centered at a certain offsets from the carrier.

Sensitivity
Sensitivity is the minimum magnitude of input signal required to produce a specified output signal having a specified signal-to-noise ratio, or other specified criteria.


Please contact us for your BK PRECISION 1652 CALIBRATION and/or BK PRECISION 1652 Triple Output DC Power Supply REPAIR

I'm interested in: 
Calibration Type (Select one):


Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: