DATRON 4707 REPAIR and DATRON 4707 CALIBRATION

 
Custom-Cal has a high success rate in the repair of the DATRON 4707. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the DATRON 4707 Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Calibrator?
Shop for Comparable Products on our
 used Calibrator page

 
   DATRON 4707   Description / Specification:    
DATRON 4707 Autocal Multifunction Standard

Datron 4707 Autocal Multifunction Standard. DC Voltage; Ranges: 100 uV to 1000V in decades. Full scale: 2 x range except 1000V range, where max output 1100V. Resolution: 1 digit in 19,999,999 or 10 nV, whichever is greater. Sensing: Selectable remote/ local sensing on 1 V to 1000V ranges. Guarding: Selectable remote/ local guarding. Settling Time: <1 s to 10 ppm of step size. Output Impedance/Max Output Current: 100 uV to 100 mV Ranges: 100 ohm. 1 V to 1000V Ranges: 25 mA max. AC Voltage Ranges: 1 mV to 1000V in decades. Full Scale: 2 x range except 1000V range, where max output 1100V. Resolution: 1 digit in 1,999 ,999 or 100 nV, whichever is greater. Frequency: Ranges: 100Hz to 1MHz in decade steps. Resolution: 1 % of range. Accuracy < ±100ppm. Sensing: Selectable remote/ local sensing on 1 V to 1000V ranges. Guarding: Selectable remote/ local guarding. Maximum Capacitive load: 1000 pF on 1V to 100V ranges, 300 pF on 1000V range. DC Current (Opt 27); Ranges: 100 uA to 1 A in decades. Full scale: 2 x range. Resolution: 1 digit in 1,999,999 or 100 pA, whichever is greater. Guarding: Selectable remote/ local guarding. AC Current; Ranges: 100 uA to 1 A in decades. Full scale: 2 x range. Resolution: 1 digit in 1,999,999 or 100 pA, whichever is greater. Guarding: Selectable remote/ local guarding. Resistance (Opt 27); Ranges: 10 ohm to 100M-ohm in decades. (Ranges are nominal, actual calibrated values are displayed). Connections: Selectable 2 or 4-wire, remote/local guard. Display Resolution: 1 digit in 19,999,999. Calibration: Autocal from front panel or via the IEEE-488 interface. OPTIONS; 17: 1000V Ranges, DCV and ACV. 27: DCI, ACI and ohm .



 

Standard Cal with Data $1,305.00 *
*This is a Web introductory price for one calibration of the DATRON 4707. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Available Gain
Available Gain is the ratio, at a specific frequency, of power available from the output to the power in from the source.

Decibel (dB)
A unit of measurement of power which indicates relative power. A -10 dB means a reduction in power by 10 times, -20 dB means another 10 times or 100 times overall, -30 means another 10 times or 1000 times overall and so on.

Mismatch Uncertainty
Mismatch Uncertainty is caused by re-reflections between one device (the source) and the device that follows it (the load).

Pulse Power
Pulse Power, the energy transfer rate is averaged over the pulse width. Pulse width is considered to be the time between the 50 percent risetime/falltime amplitude points. Pulse power averages out any aberrations in the pulse envelope such as overshoot or ringing.


Please contact us for your DATRON 4707 REPAIR and/or DATRON 4707 Autocal Multifunction Standard CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: