Keysight (Agilent) 8711C REPAIR and Keysight (Agilent) 8711C CALIBRATION

 
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) 8711C. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 8711C Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Network Analyzer, SNA, VNA?
Shop for Comparable Products on our
 used Network Analyzer, SNA, VNA page or new Network Analyzer, SNA, VNA page

 
   Keysight (Agilent) 8711C   Description / Specification:    
Keysight (Agilent) 8711C RF Economy Network Analyzer

The HP 8711C RF economy network analyzer provides speed, accuracy, and measurement versatility in a compact, integrated instrument for high-volume RF component manufacturing, inspection, and maintenance. An integrated synthesized source and transmission/reflection test set enable complete swept frequency characterization of RF components with a single connection. For testing narrowband devices, the internal synthesized source provides a fast (50 ms/sweep), stable (1 Hz resolution) stimulus. Calculate and display specified device characteristics in real time. Eight markers per channel, marker search, tracking, bandwidth, and a variety of math functions speed component testing. Source Characteristics; Frequency Range: 300 kHz to 1.3 GHz. Frequency Resolution: 1 Hz. Accuracy: <5 ppm. Output Characteristics; Power Range (standard): <1000 MHz, 0 to 16 dBm (>1000 MHz, 0 to 13 dBm). Test Port Accuracy and Flatness: ±1.0 dB. Signal Purity Harmonics (at +7 dBm): <1 MHz, <-20 dBc (>1 MHz, <-30 dBc). Receiver Characteristics; Frequency Range: Narrowband 300 kHz to 1.3 GHz, Broadband 10 MHz to 1.3 GHz. AM Delay Characteristics; Apertures: 55.56 kHz. Input Amplifier Range: -10 to +13 dBm. Resolution: 0.5 ns. Range: 30 µs (9000 m). Accuracy: ±4 ns. Test Set Characteristics; Reflection Port Match: 30 dB. Transmission Port Match: 18 dB typical. System Directivity: 40 dB. Options: 1EC, 75 ohm System Impedance. 1E1, 60 dB Attenuator. 1C2, IBASIC Capability. 1DA, 50 ohm AM Delay. 1DB, 75 ohm AM Delay. 1CL, DIN Keyboard. 1CM, Rackmount. 100, Fault Location/SRL. 101, Transportable Operating Case plus Fault Location/SRL. 1F7, LAN Interface.



 

Standard Calibration $675.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 8711C. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related RF Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBc
dBc (decibels relative to the carrier) is the power ratio of a signal to a carrier signal, expressed in decibels. If the dBc figure is positive, then the relative signal strength is greater than the carrier signal strength. If the dBc figure is negative, then the relative signal strength is less than carrier signal strength.

Noise Density
Noise Density is the amount of noise within a defined bandwidth, usually normalized to 1 Hz.

Spurious Signals
Spurious signals are undesired signals. They can be considered in two classes. They can be stationary; their frequency and amplitude do not change significantly, or non-stationary, where the frequency and/or amplitude change significantly over short time periods.


Please contact us for your Keysight (Agilent) 8711C REPAIR and/or Keysight (Agilent) 8711C RF Economy Network Analyzer CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: