Keysight (Agilent) E4866A REPAIR and Keysight (Agilent) E4866A CALIBRATION

 
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) E4866A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) E4866A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Pattern Generator?
Shop for Comparable Products on our
 used Pattern Generator page

 
   Keysight (Agilent) E4866A   Description / Specification:    
Keysight (Agilent) E4866A ParBERT Generator Module, VXI

Agilent E4866A ParBERT 10.8 Gb/s Generator Module (VXI). Data range 9.5 Gbit/s to 10.8 Gbit/s. Clock range: 9.5 GHz to 10.8 GHz. Delay Range: 0 to 300 ns. Delay Resolution: 1 ps. Accuracy: ±20 ps ± 50 ppm relative to the zero-delay placement. Skew between modules of same type: 50 ps typ. after deskewing at customer levels and unchanged system frequency. Segment length resolution: 256bits. Patterns: Memory-based up to 33,554,432bits, PRBS/PRWS 2^n -1, n= 7, 9, 10, 11, 15, 23, 31. Marker Density: 1/8, 1/4, 1/2, 3/4, 7/8 at 2^n -1, n=7, 9, 10, 11, 15. Errored PRBS/PRWS: 2^n -1, n= 7, 9, 10, 11, 15. Extended ones or zeros: 2^n -1, n= 7, 9, 10, 11, 15. Clock patterns: Divide or multiply by 1, 2, 4. Output: 1, single ended, AC coupled, to be used into 50 Ohm. Duty cycle 50% typical. Maximum external voltage: -2.2V to +3.3 V. Amplitude/Resolution: 0.5Vpp fixed typ. Transition times (20%-80%): sine wave. Clock Jitter < 2ps RMS.



 

Standard Calibration $700.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) E4866A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Communication Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

Accuracy
Accuracy is the degree of closeness of measurements of a quantity to that quantity's actual (true) value.

Jitter
Jitter in technical terms is the deviation in or displacement of some aspect of the pulses in a high-frequency digital signal. Jitter is the time variation of a periodic signal in electronics and telecommunications, often in relation to a reference clock source. Jitter may be observed in characteristics such as the frequency of successive pulses, the signal amplitude, or phase of periodic signals. Jitter is a significant, and usually undesired, factor in the design of almost all communications links (e.g., USB, PCI-e, SATA, OC-48). In clock recovery applications it is called timing jitter.

Receiver Sensitivity
Receiver Sensitivity is the optical power required by a receiver for low error signal transmission. In the case of digital signal transmission, the mean optical power is usually quoted in Watts or dBm (decibels referred to 1 milliwatt).


Please contact us for your Keysight (Agilent) E4866A REPAIR and/or Keysight (Agilent) E4866A ParBERT Generator Module, VXI CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: