Keysight (Agilent) DSO81004A CALIBRATION and Keysight (Agilent) DSO81004A REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) DSO81004A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope?
Shop for Comparable Products on our
 used Oscilloscope page

 
   Keysight (Agilent) DSO81004A   Description / Specification:    
Keysight (Agilent) DSO81004A 4 Ch 10 GHz Infiniium Oscilloscope

The Agilent DSO81004A 4 Ch Infiniium Oscilloscope combines unprecedented ease-of-use with high-performance digitizing oscilloscope functionality to simplify your design and analysis measurement tasks. It offers 4 channels, 20 GSa/s sampling rate on all four channels, 10 GHz bandwidth. Graphical user interface with menus, windows, dialogs, and toolbars provides easy access to dozens of configuration and analysis tools, ensuring you can set up and make the most complex measurements. Specifications. Bandwidth: 10 GHz real-time on 2 channels, 40 GSa/s. Standard acquisition memory: 0.5 Mpts on 2 channels, 0.25 Mpts on 4 channels. Optional acquisition memory: 2 Mpts on 2 channels, 1 Mpts on 4 channels. Maximum memory in equivalent-time modes: always 0.25 Mpts per channel. Rise time/fall time: 30 ps (20 - 80%), 42 ps (10 - 90%). Input impedance: 50 ohm ± 3%. Sensitivity: 1 mV/div to 1 V/div. Input coupling: DC. Vertical resolution: 8 bits, = 12 bits with averaging. Channel to channel isolation (any two channels with equal V/div settings): DC to 3 GHz: 60 dB, 3 GHz to 8 GHz: 40 dB, 8 GHz to BW: 35 dB. DC gain accuracy: ± 2% of full scale at full resolution channel scale. Maximum input voltage: ± 5 V. Main timebase range: 5 ps/div to 20 s/div real-time, 5 ps/div to 500 ns/div equivalent-time. Main timebase delay range: –200 s to 200 s real-time, –25 µs to 200 s equivalent-time. Delayed timebase range: 1 ps/div to current main time scale setting. Channel deskew: ± 25 µs range, 100 fs resolution. Time scale accuracy: ± 1 ppm pk. Maximum real-time sample rate: 40 GSa/s (2 channels simultaneously), 20 GSa/s (4 channels simultaneously). Memory depth per channel Standard: 524,288 (2 channels), 262,144 (4 channels). Trigger Sensitivity: 2.0 div p-p 0 to 5 GHz (Internal Low), 0.3 div p-p 0 to 4 GHz, 1.0 div p-p 4 to 7.5 GHz (Internal High). Level range Internal: ± 4 div from center screen or ± 4 Volts, whichever is smallest. Sweep modes: Auto, triggered, single. Options: 001: 2 M (2 channels), 1 M (4 channels) memory upgrade, 64 M (2 channels at 4 GSa/s) or 32 M (4 channels = 2 GSa/s). 002: EZJIT jitter analysis software (installed at the factory). 003: High-Speed Serial Data Analysis/Mask Testing with clock recovery and 8b/10b decoding (installed at the factory). 004: EZJIT Plus jitter analysis software (installed at the factory). 005: Noise reduction software (installed at the factory). 006: My Infiniium Integration Package (installed at the factory). 017: 20 Gb removable hard disk drive. Replaces internal hard disk with a removable hard disk. Order the N5390A for additional hard disk drive cartridges.



 

Standard Calibration $650.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) DSO81004A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBm
dBm (sometimes dBmW) is an abbreviation for the power ratio in decibels (dB) of the measured power referenced to one milliwatt (mW). Zero dBm equals one milliwatt. A 3 dB increase represents roughly doubling the power, a 3 dB decrease, the power is reduced by about one half.

Millimeter-wave
Millimeter-wave is a term that generally refers to frequencies of 26.5 GHz and above. That is where signal wavelengths fall below approximately 10 mm, and thus the terminology changes from centimeters to millimeters.

Power Repeatability
Power Repeatability is the random uncertainty in reproducing the power level after changing and re-setting the power level. The power repeatability is ± half the span (in dB) between the highest and lowest actual power. Note: - The long-term power repeatability can be obtained by taken the power repeatability and power stability into account.

Stability
Stability is the extent to which a specified property, characteristic, or parameter of a substance, device, or apparatus, remains fixed with the passage of time or with varying environmental conditions.


Please contact us for your Keysight (Agilent) DSO81004A CALIBRATION and/or Keysight (Agilent) DSO81004A 4 Ch 10 GHz Infiniium Oscilloscope REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: