Keysight (Agilent) 35670A REPAIR and Keysight (Agilent) 35670A CALIBRATION

 
Custom-Cal has a high success rate in the repair of the Keysight (Agilent) 35670A. A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 35670A Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Signal Analyzer?
Shop for Comparable Products on our
 used Signal Analyzer page

 
   Keysight (Agilent) 35670A   Description / Specification:    
Keysight (Agilent) 35670A Dynamic Signal Analyzer

The HP 35670A Dynamic Signal Analyzer lets you make laboratory-quality measurements in the field, on an automobile test track, flying above a city, or in the narrow confines of a submarine. Small enough to fit under an airplane seat, the HP 35670A is a two, or four-channel (Option AY6), FFT-based spectrum/network analyzer. The standard instrument provides spectrum, network, time-domain, and amplitude-domain measurements from virtually dc to slightly over 100 kHz. Your ability to solve problems in the field is enhanced with the optional four-channel HP 35670A-measure noise at multiple locations inside vehicles, make triaxial vibration measurements, or gather data from several locations along a noise transmission path. Source. Swept and fixed sine, random (white and pink) noise, burst random, chirp, burst and periodic chirp, and arbitrary waveform. Measurement capabilities. Transfer functions–magnitude/phase, curve fit, spectrum analysis, octave analysis, order domain spectrum analysis, order tracking, histogram analysis. HP-IB programmable. Specifications. Frequency range: 0.000122 Hz to 102.4 kHz (2 channel), 0.000122 Hz to 51.2 kHz (4 channel). Channel Match: ± 0.04 dB, ± 0.5°. Frequency resolution in lines: 100 to 1600. Real-time bandwidth: 25.6 kHz. Dynamic range: 80 dB, 90 dB typ. Amplitude accuracy. 0.15 dB. Options. Opt AY6: Add 2 Input Channels. Opt 1D0: Computed Order Tracking Measurements. Opt 1D1: Real-Time Octave Measurements. Opt UK4: Microphone Adaptor and Power Supply. Opt 1D2: Swept-Sine Measurements. Opt 1D3: Curve Fit/Synthesis. Opt 1D4: Arbitrary Waveform Source. Opt 1C2: HP Instrument BASIC. Opt AN2: Add 4 MB Memory. Opt UFC:Add 8 MB RAM. Opt 100: Software Bundle. Opt UFF: Add 1 MB Nonvolatile RAM.



 

Standard Calibration $550.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 35670A. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBc
dBc (decibels relative to the carrier) is the power ratio of a signal to a carrier signal, expressed in decibels. If the dBc figure is positive, then the relative signal strength is greater than the carrier signal strength. If the dBc figure is negative, then the relative signal strength is less than carrier signal strength.

Load Regulation
Load regulation is the capability to maintain a constant voltage (or current) level on the output channel of a power supply despite changes in the supply's load (such as a change in resistance value connected across the supply output).

Power Linearity
When changing the power level and measuring the differences (in dB) between actual and displayed power levels, the power linearity is ± half the span (in dB) between the maximum and the minimum value of all differences.

Settling Time
Settling time of an output device is the time elapsed from the application of an ideal instantaneous step input to the time at which the amplifier output has entered and remained within a specified error band, usually symmetrical about the final value.


Please contact us for your Keysight (Agilent) 35670A REPAIR and/or Keysight (Agilent) 35670A Dynamic Signal Analyzer CALIBRATION

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: