Keysight (Agilent) 54510B CALIBRATION and Keysight (Agilent) 54510B REPAIR

 
A calibration by Custom-Cal is performed by engineers with extensive OEM experience. We have the expertise and the necessary standards to perform the Keysight (Agilent) 54510B Calibration, onsite calibration may be available. We specialize in quick turnaround times and we can handle expedited deliveries upon request.

Need another Oscilloscope?
Shop for Comparable Products on our
 used Oscilloscope page

 
   Keysight (Agilent) 54510B   Description / Specification:    
Keysight (Agilent) 54510B 2 Ch 300 MHz Digitizing Oscilloscope

The HP 54510B is a 300 MHz, 1 GSa/s sample rate, 2-channel digitizing oscilloscope. Use it to trigger on a wide variety of user-specified conditions. Trigger on edge, pattern, state, or trigger after delay to capture such elusive events as timing violations or transient bus phenomena. To pinpoint infrequent events and determine their cause, use HP's advanced logic triggering in conjunction with up to four channels to quickly isolate anomalies. Triggering on an anomaly will allow you to probe other points within the system during the failure condition to understand the cause of tbe problem quickly. If you are characterizing several events separated in time, the sequential single-shot capability allows you to capture the pulses without dead time in between. You can then analyze the pulses individually or all together in normal, averaged, or envelope mode. Specifications. Repetitive Bandwidth: 300 MHz (equivalent time). Number of channels (simultaneous acquisition): 2. Vertical sensitivity range: 1 mV/div to 5 V/div. Vertical dc gain Accuracy: ± 1.25% of full scale. Vertical resolution: 8 bits (10 bits via HP-IB with averaging). Maximum sample rate (Real time mode): 1 GSa/s on all channels). Waveform record length: 8001 points (real-time), 501 points (repetitive). Maximum input: 1 M-ohm: ± 250 V [dc + peak ac < 10kHz)], 50 ohm: 5 V rms. Time base range: 1 ns/div to 5 s/div. Resolution: 20 ps. Trigger Pulse width (minimum): Internal 1.75 ns, External 2.8 ns.



 

Standard Calibration $325.00 *
Click on Logo for More Prices
*This is a Web introductory price for one calibration of the Keysight (Agilent) 54510B. Price does not in most cases include measurement performance data. Pricing does include NIST traceable calibration and issue of a calibration certificate and calibration label. Pricing may vary slightly due to volume and location of laboratory supporting calibration. Volume pricing may apply. On-site fees may apply depending on logistics, location and volume of work to be completed during the visit.


Related Bench Equipment Terms and Definitions. For a complete list go to our  Terms and Definitions Page.

dBc
dBc (decibels relative to the carrier) is the power ratio of a signal to a carrier signal, expressed in decibels. If the dBc figure is positive, then the relative signal strength is greater than the carrier signal strength. If the dBc figure is negative, then the relative signal strength is less than carrier signal strength.

Load Regulation
Load regulation is the capability to maintain a constant voltage (or current) level on the output channel of a power supply despite changes in the supply's load (such as a change in resistance value connected across the supply output).

Power Linearity
When changing the power level and measuring the differences (in dB) between actual and displayed power levels, the power linearity is ± half the span (in dB) between the maximum and the minimum value of all differences.

Settling Time
Settling time of an output device is the time elapsed from the application of an ideal instantaneous step input to the time at which the amplifier output has entered and remained within a specified error band, usually symmetrical about the final value.


Please contact us for your Keysight (Agilent) 54510B CALIBRATION and/or Keysight (Agilent) 54510B 2 Ch 300 MHz Digitizing Oscilloscope REPAIR

I'm interested in: 
Calibration Type (Select one):
Repair Information:
 Serial Number:

 Is there any physical damage?  
 If yes, describe:


What is the description of the problem?

How/when did the problem start?


 (*) Required Fields    For formal quote please fill in all fields.
Company:
From (Email):*
Contact Name:*
Country:*
Address 1:
Address 2:
City:
State/Territory/Province: *
Zip/Postal Code:
Phone:*

Comment: